White-Rodgers 36C03-333

White-Rodgers 36C03-333 Standing Pilot Gas Valve Instruction Manual

Модел: 36C03-333

1. Увод

This manual provides essential instructions for the proper installation, operation, and maintenance of the White-Rodgers 36C03-333 Standing Pilot Gas Valve. This valve is designed for use in heating systems requiring a standing pilot ignition. Please read this manual thoroughly before attempting any installation or service to ensure safe and efficient operation.

White-Rodgers 36C03-333 Standing Pilot Gas Valve

Figure 1: White-Rodgers 36C03-333 Standing Pilot Gas Valve. A close-up view of the White-Rodgers 36C03-333 Standing Pilot Gas Valve, showing its metal construction and various connection points.

2. Безбедносне информације

УПОЗОРЕЊЕ: Неправилна инсталација, подешавање, преинаке, сервис или одржавање могу узроковати оштећење имовине, повреде или смрт. Пажљиво прочитајте упутства за инсталацију, рад и одржавање пре инсталирања или сервисирања ове опреме.

  • Always shut off the main gas supply before installing or servicing the gas valve.
  • Ensure all electrical connections are disconnected before working on the unit.
  • Verify that the gas type (Natural Gas or LP) matches the valve's configuration. An LP conversion kit is included for flexibility.
  • All work should be performed by a qualified technician in accordance with local codes and regulations.
  • Check for gas leaks using a soap solution after installation; never use an open flame.

3. Подешавање и инсталација

The White-Rodgers 36C03-333 gas valve is designed for standing pilot ignition systems. Follow these general steps for installation:

  1. Припрема: Turn off the main gas supply and electrical power to the appliance. Allow the appliance to cool.
  2. Уклоните стари вентил: Disconnect all gas piping and electrical wiring from the existing gas valve. Carefully remove the old valve.
  3. Инсталирајте нови вентил: Apply appropriate pipe sealant to all threaded connections. Install the new White-Rodgers 36C03-333 valve, ensuring correct orientation. The valve features a 1/2 inch inlet and a 3/4 inch outlet. A reducer bushing kit (3/4 x 1/2 In. and 1/2 x 3/8 In.) is provided for adapting to various pipe sizes.
  4. Електричне везе: Connect the 24VAC wiring to the appropriate terminals on the valve. For systems requiring only two wires to energize the gas valve solenoid, connect them to the outer 'TH' and 'TR' terminals. If your system has a high-temperature safety switch already in series with the 24VAC transformer power, you may use the included jumper to bypass the unneeded high-temperature safety connection on the valve.
  5. Gas Type Conversion (if necessary): If converting from Natural Gas to LP or vice-versa, use the included LP conversion kit and follow its specific instructions.
  6. Тест цурења: After all connections are made, slowly turn on the main gas supply. Check all gas connections for leaks using a non-corrosive soap solution. Bubbles indicate a leak. Tighten connections as needed and re-test.
  7. Pilot Light Adjustment: Refer to the appliance manufacturer's instructions for lighting and adjusting the pilot flame.

4. Упутство за употребу

The White-Rodgers 36C03-333 is a standing pilot gas valve. This means a small pilot flame remains lit continuously, ready to ignite the main burner when heat is called for.

  1. Осветљење пилота: Follow the specific instructions provided by your appliance manufacturer. Generally, this involves turning the gas control knob to the 'PILOT' position, pressing and holding it down, and then lighting the pilot burner. Continue holding the knob for about 30-60 seconds until the thermocouple heats up and holds the pilot flame.
  2. Main Burner Operation: Once the pilot is lit and stable, turn the gas control knob to the 'ON' position. When the thermostat calls for heat, the 24VAC coil in the gas valve will energize, opening the main gas flow to the burner, which will then be ignited by the standing pilot flame.
  3. Искључивање: To turn off the appliance, turn the gas control knob to the 'OFF' position. This will shut off both the main burner and the pilot flame.

5. Одржавање

The White-Rodgers 36C03-333 gas valve is designed for reliable operation with minimal maintenance. However, periodic checks are recommended to ensure continued safe and efficient performance.

  • Годишња инспекција: It is recommended to have a qualified HVAC technician inspect your heating system, including the gas valve, annually.
  • Провера пилотског пламена: Periodically observe the pilot flame. It should be a steady, blue flame enveloping the tip of the thermocouple. A weak, yellow, or wavering flame may indicate a dirty pilot orifice or other issues.
  • чистоћа: Одржавајте простор око гасног вентила чистим и без прашине, остатака и препрека.
  • Везе: Ensure all gas and electrical connections remain tight and free from corrosion.

КСНУМКС. Решавање проблема

Пре него што покушате да решите било какав проблем, уверите се да је главни довод гаса укључен и да је уређај снабдевен електричном енергијом. Ако нисте сигурни у вези са било којим кораком, обратите се квалификованом сервисеру.

ПроблемМогући узрокРешење
Pilot light will not stay lit
  • Dirty or faulty thermocouple
  • Слаб пилотски пламен
  • Internal electromechanical safety shutoff valve issue
  • Clean or replace thermocouple
  • Adjust pilot flame (if possible)
  • Inspect pilot orifice for blockage
  • If the issue persists, the gas valve may need replacement.
Main burner does not ignite
  • Пилот светло није упаљено
  • No call for heat from thermostat
  • Faulty 24VAC wiring or transformer
  • Gas valve solenoid failure
  • Light pilot light
  • Check thermostat settings and ensure it's calling for heat
  • Verify 24VAC power to the valve terminals using a voltmeter
  • If 24VAC is present but the valve doesn't open, the valve may be faulty.
Откривен мирис гасаЦурење гасаImmediately shut off gas supply. Ventilate the area. Do not operate any electrical switches. Contact a qualified technician or your gas company immediately.

7. Спецификације

ФеатуреДетаљ
Број модела36Ц03-333
БрандВхите-Родгерс
Тип паљењаСтојећи пилот
BtuH Capacity230,000
Тип вентилаFast Opening
Coil Volts24 ВАЦ
Тип гасаNatural Gas / LP (LP Conversion Kit Included)
Величина улазног прикључка1/2 инча
Тип улазног прикључкаФИП
Величина прикључка на излазу3/4 инча
Тип прикључка на излазуФИП
Комплет чахура редуктора3/4 x 1/2 In. and 1/2 x 3/8 In.
Сиде ТапсДа
Распон температуре околине-40 до 175 степени Ф
Ampс АЦ0.23
Опсег подешавања притиска2.5 to 5.0 In. WC
МатеријалМетал
Ектериор Финисхнерђајући челик
Димензије производа (Д к Ш к В)5 к 6.5 к 4 инча
Тежина артикла1.2 фунти
ЦертификатиETL, ULC
УПЦ / ГТИН786710005657
ПроизвођачAPR Supply Co.

8. Гаранција и подршка

Информације о гаранцији: Specific warranty terms and conditions for the White-Rodgers 36C03-333 Standing Pilot Gas Valve are provided by the manufacturer. Please refer to the documentation included with your purchase or visit the official White-Rodgers webза детаљне информације о гаранцији.

техничка подршка: For technical assistance, installation questions, or service inquiries, please contact a qualified HVAC professional. You may also reach out to White-Rodgers customer support directly through their official website or contact information provided with the product packaging.

© 2023 White-Rodgers. All rights reserved. This manual is for informational purposes only.