Sicce 925607

Sicce Ultrazero Flat Sucking Pump Instruction Manual

Модел: 925607

1. Производ је готовview

The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.

Кључне карактеристике:

  • Capable of pumping water down to 2 mm residual level.
  • Fully submersible design.
  • Handles dirt particles up to 3 mm in size.
  • Equipped with a 10-meter power cable.
  • Features a practical carry handle for easy transport.
Sicce Ultrazero Flat Sucking Pump

Слика 1: Завршеноview of the Sicce Ultrazero Flat Sucking Pump.

2. Безбедносне информације

Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect the pump from the power supply before handling, cleaning, or performing any maintenance.
  • Уверите се да је напајање волtage matches the pump's specifications (230 V/50 Hz).
  • Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
  • Do not use the pump to handle flammable or explosive liquids.
  • Држите децу и неовлашћена лица даље од радног простора.
  • Уверите се да је пумпа потпуно потопљена током рада како бисте спречили прегревање.
  • Avoid running the pump dry for extended periods.
  • This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.

3. Подешавање и инсталација

Follow these steps to properly set up your Ultrazero pump:

  1. Распакујте пумпу: Пажљиво извадите пумпу и сву додатну опрему из паковања. Проверите да ли има оштећења.
  2. Connect the Discharge Hose:

    The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

    Pump outlet and handle

    Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.

  3. Поставите пумпу: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
  4. Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
  5. Прикључак за напајање: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.
База пумпе

Figure 3: The flat base of the pump designed for low residual water levels.

4. Упутство за употребу

The Ultrazero pump is designed for simple operation:

  1. Потопите пумпу: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
  2. Започните пумпање: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
  3. Пратите ниво воде: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
  4. Stop Pumping: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.
Pump draining a small pool

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Pump draining a flooded floor

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Pump showing 2mm residual water level

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.

5. Одржавање

Редовно одржавање осигурава дуготрајност и оптималне перформансе ваше пумпе.

  • Чишћење: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
  • Прегледајте има ли остатака: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
  • Инспекција каблова: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
  • Складиштење: When not in use, store the pump in a clean, dry place, protected from frost.
Pump used for garden watering

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.

КСНУМКС. Решавање проблема

If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:

ПроблемМогући узрокРешење
Пумпа се не покреће.Нема напајања.
Кабл за напајање оштећен.
Заштита од преоптерећења мотора је активирана.
Проверите прикључак за напајање и утичницу.
Inspect cable for damage; replace if necessary (by qualified personnel).
Disconnect power, allow motor to cool, then reconnect.
Пумпа ради, али вода се не испушта.Intake blocked.
Црево за пражњење је савијено или зачепљено.
Airlock in pump.
Disconnect power, clear intake.
Проверите и очистите црево за пражњење.
Briefly lift and lower the pump while submerged to release trapped air.
Reduced pumping performance.Partial blockage.
Impeller worn.
Disconnect power, clean pump intake and impeller area.
За услугу контактирајте корисничку подршку.
Пумпа се неочекивано зауставља.Overheating due to low water level or blockage.
Електрична грешка.
Disconnect power, check water level and clear blockages. Allow to cool.
Ако проблем и даље постоји, контактирајте корисничку подршку.

If the problem persists after attempting these solutions, please contact Sicce customer support.

7. Техничке спецификације

Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:

СпецификацијаВалуе
БрандСиче
Број модела925607
Max. Delivery Rate (Flow Rate)3000 л/х
Макс. Висина испоруке3.1 м
Power Consumption (P1)80 В
Оператинг Волtage220-240 В / 50 Хз
Conductor Length (Power Cable)10 m (three-core, indoor and outdoor use)
Прикључак под притиском26.44 mm (3/4") AG
Hose Connection Diameter20 mm (3/4")
Max. Solids Size3 мм
Преостали ниво водеDown to 2-3 mm
Димензије производа (приближно)140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3"
Тежина артикла2.6 кг (5.72 лбс)
Пливајући прекидачбр
Заштита од преоптерећењаNo (Internal thermal protection may exist, but no external reset)
ПореклоПроизведено у Италији
Technical drawing with pump dimensions

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.

8. Гаранција и подршка

For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.

Произвођач: Ebara

Бренд: Сиче

For further assistance, visit the official Sicce webсајт или контактирајте свог локалног дистрибутера.

© 2026 Sicce. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.