1. Производ је готовview
The DIGITUS DN-93903 LSA connection module is designed for connecting or extending twisted pair cables. It provides excellent performance and connection quality for your network infrastructure.
This shielded Cat 6 LSA insulation displacement connector supports transmission characteristics up to 250 MHz and 1GBase-T applications. It is suitable for AWG 22 to AWG 26 solid and stranded conductors.
The module is versatile, suitable for installation in cable ducts, flush-mounted, and surface-mounted applications. It is ideal for extending existing cables or replacing defective cable sections in your network setup.

Image: The DIGITUS LSA connection module showing the internal LSA terminals with color-coded wiring for EIA/TIA 568 A & B standards. An Ethernet cable is connected to a wall outlet, illustrating a typical application.
2. Упутства за подешавање
Follow these steps to properly install and connect the DIGITUS DN-93903 LSA connection module:
- Припремите каблове: Strip approximately 2-3 cm of the outer jacket from the installation cables you intend to connect. Ensure the twisted pairs remain intact.
- Open Module: Carefully open the LSA connection module to access the LSA insulation displacement terminals.
- Завршетак жице: Refer to the color-coded wiring diagram on the LSA terminals (EIA/TIA 568 A or B standard). Untwist the wire pairs minimally and place each individual wire into the corresponding slot on the LSA terminal.
- Сигурне жице: Use an LSA punch-down tool (not included) to press each wire firmly into its slot. The tool will simultaneously cut off any excess wire. Ensure a secure connection.
- Integrated Strain Relief: Utilize the integrated strain relief mechanism to secure the incoming cables, preventing accidental disconnections or damage.
- Close Module: Once all wires are correctly terminated and secured, carefully close the module housing.
- Монтажа: Mount the module in your desired location (panel, flush-mounted box, or surface-mounted) using appropriate fasteners (not included).
3. Упутство за употребу
The DIGITUS DN-93903 LSA connection module is a passive component designed for permanent cable connections. Once installed, it operates without user intervention.
- Функција: The module extends or connects two network installation cables, maintaining the Cat 6 performance standards.
- Повезивање: Ensure that the connected cables are properly terminated and connected to active network equipment (e.g., switches, routers) for network functionality.
- Перформансе: When correctly installed, the module facilitates data transmission up to 1 Gigabit Ethernet (1GBase-T) with a bandwidth of 250 MHz.
4. Одржавање
The DIGITUS DN-93903 LSA connection module requires minimal maintenance due to its robust design.
- Чишћење: Keep the module free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
- Услови животне средине: Ensure the module is installed in a dry indoor environment, away from excessive moisture, heat, or direct sunlight.
- Инспекције: Periodically check the cable connections for any signs of wear, damage, or loose wires. Re-terminate if necessary.
КСНУМКС. Решавање проблема
If you experience network connectivity issues after installing the LSA connection module, consider the following troubleshooting steps:
- Нема мрежне везе:
- Verify that all wires are correctly terminated according to the EIA/TIA 568 A or B standard. Incorrect wiring is a common cause of connection failure.
- Ensure that the LSA punch-down tool was used correctly, making firm contact and cutting excess wire.
- Check the integrity of the connected network cables. Test them individually if possible.
- Confirm that all active network equipment (router, switch, PC) is powered on and functioning correctly.
- Мала брзина мреже:
- Ensure that all connections are secure and that no wires are loose or partially disconnected.
- Verify that the cables used are Cat 6 compliant to match the module's performance.
- Check for external interference if the module is installed near power cables or other sources of electromagnetic interference. The module is shielded, but proper installation practices are still important.
- Интермитентна веза:
- Re-examine the LSA terminations for any wires that may have come loose or were not fully seated.
- Ensure the module housing is securely closed and the strain relief is properly applied.
6. Спецификације
| Феатуре | Опис |
|---|---|
| Модел | ДН-КСНУМКС |
| Карактеристике преноса | Категорија 6 |
| Подручја примене | Up to 250 MHz, 1GBase-T |
| Стандарди | ISO/IEC 11801 3rd Edition, EN 50173-1, EIA/TIA 568-C, ANSI, UL |
| Врста инсталације | Suitable for duct, flush-mounted, and surface-mounted installation |
| Цабле Инсталлатион | LSA-strips, color-coded according to EIA/TIA 568 A & B |
| Conductor Acceptance | AWG 22-26 solid and stranded conductors |
| Материјал кућишта | ABS UL-94V-0 |
| RJ45 Jack Contact Material | Nickel-plated phosphor bronze, 0.5 µ gold-plated contact |
| RJ-45 Shielding Material | Nickel-plated bronze |
| LSA Cutting Clamp Материјал | Krone LSA+, UL 94V-0, galvanized phosphor bronze |
| ПЦБ | FR4, UL 94V-0 |
| Радна температура | -20°Ц до +70°Ц |
| Отпорност изолације | > 500 МОхм |
| Контакт отпор | < 20 milliOhm |
| Диелектрична чврстоћа | 1000 VDC (contact/contact), 1500 VDC (contact/ground) |
| Димензије производа (Д x Ш x В) | 15 Д x 9 Ш x 3 В центиметара |

Слика: Крупни план view of the DIGITUS LSA connection module, illustrating its compact size with dimensions of 2.6 inches (6 cm) in length.
7. Гаранција и подршка
Информације о гаранцији
This DIGITUS DN-93903 LSA Connection Module comes with a Двогодишња законска гаранцијаМолимо вас да сачувате доказ о куповини за евентуалне рекламације.
Техничка подршка
For technical assistance, installation queries, or troubleshooting beyond the scope of this manual, please contact DIGITUS customer support. Refer to the official DIGITUS webвеб-сајт или паковање вашег производа за најновије контакт информације.
When contacting support, please have your product model number (DN-93903) and a detailed description of your issue ready.