The AEMC Model 3711 is a portable clamp-on ground resistance tester designed for measuring electrical ground rod and grid resistance in multi-grounded systems. This instrument offers a non-intrusive method for testing without the need for auxiliary rods or disconnecting the ground system. It also measures leakage, neutral, and phase currents, providing a comprehensive solution for electrical system analysis.

Безбедносне информације

УПОЗОРЕЊЕ: Always read and understand all safety instructions before operating this instrument. Failure to do so may result in serious injury or death.

  • This instrument is rated CAT III, indicating its suitability for measurements in building installations.
  • Adhere to all local and national safety codes and regulations.
  • Do not use the instrument if it appears damaged or is operating abnormally.
  • Ensure the battery compartment is securely closed before use.
  • Avoid contact with live circuits during measurement.
  • The instrument is double-insulated for enhanced safety.

Шта је у кутији

Проверите да ли су сви предмети присутни приликом распакивања:

  • AEMC Ground Resistance Tester Model 3711
  • Calibration Check Loop, 25Ω
  • Хард Царриинг Цасе
  • 9В алкална батерија
  • Кориснички приручник (овај документ)

Производ је завршенview

AEMC Model 3711 Clamp-On Ground Resistance Tester showing a reading of 9.8 Ohms on its display.

Image: The AEMC Model 3711 Clamp-On Ground Resistance Tester. This image displays the device with its red clamp jaws open, a black body, and a green digital display showing "9.8 Ω". Control buttons are visible below the display.

The AEMC Model 3711 features an ergonomic design for one-handed operation. Its robust polycarbonate construction ensures durability for outdoor use. Key components include:

  • Clamp чељусти: 1.25" opening to accommodate ground rods and cables up to 1000kcmil.
  • ЛЦД екран: Digital readout for resistance and current measurements.
  • Контролна дугмад: For power, data hold, and mode selection.
  • Одељак за батерије: Located at the rear for a 9V battery.

Подешавање и инсталација батерије

  1. Open the battery compartment cover on the rear of the instrument.
  2. Insert the supplied 9V Alkaline battery, observing correct polarity.
  3. Добро затворите поклопац одељка за батерије.
  4. Press the "ON" button to power on the device. The display should illuminate.

Упутство за употребу

Ground Resistance Measurement

  1. Power on the AEMC 3711.
  2. Отворите цлamp jaws by pressing the release lever.
  3. Ставите цлamp around the ground conductor or rod to be tested, ensuring the jaws are fully closed.
  4. The instrument will automatically measure and display the ground resistance in Ohms (Ω).
  5. For stable readings, allow approximately one second for the measurement to settle.
  6. To hold the current reading on the display, press the "HOLD" button. Press again to release.

Цуррент Меасуремент

  1. Power on the AEMC 3711.
  2. Отворите цлamp чељуст.
  3. Ставите цлamp around the conductor carrying the current to be measured (leakage, neutral, or phase current). Ensure the jaws are fully closed.
  4. The instrument will automatically measure and display the current in Ampерес (А) или миллиAmpерес (мА).
  5. The current measurement function provides direct readings for leakage current flowing to ground or circulating in ground loops (down to 1mA) and neutral/phase currents (up to 30A RMS).

Одржавање и калибрација

Чишћење

Очистите инструмент меком, дamp тканина. Немојте користити абразивна средства за чишћење или раствараче.

Замена батерије

When the low battery indicator appears on the display, replace the 9V battery as described in the "Setup and Battery Installation" section.

Провера калибрације

Use the supplied 25Ω calibration check loop to verify the instrument's accuracy periodically. Clamp the tester around the loop; the reading should be approximately 25Ω. If the reading deviates significantly, contact AEMC customer support for service.

Складиштење

Store the instrument in its hard carrying case in a dry, cool environment when not in use. Remove the battery if storing for extended periods.

Решавање проблема

  • No Display/Instrument Not Powering On: Проверите да ли је батерија инсталирана и уверите се да је довољно напуњена. Замените је ако је потребно.
  • Нестабилна очитавања: Осигурајте да цлamp jaws are fully closed around the conductor. Verify there is no excessive electrical noise in the environment.
  • "OL" or Overload Indication: The measured value exceeds the instrument's range. Ensure the correct measurement function is selected or the circuit parameters are within the device's limits.
  • Нетачна очитавања: Perform a calibration check using the 25Ω loop. If the issue persists, contact technical support.

Спецификације

ПараметарВалуе
Ground Resistance RangeAutoranging 0.01 to 1200Ω
Опсег мерења струјеAutoranging 1mA to 30.00A RMS
Resistance Measuring Frequency2403Хз
Current Measuring Frequency47 до 800 Хз
Accuracy (Resistance)±2% reading ±0.02Ω (up to 25% of reading for 600-1200Ω)
Радна температура-10 до 55°Ц (14 до 131°Ф)
Извор напајања9В батерија (укључена)
Тежина1 кг (2.2 лбс)
Димензије (В к Ш к Д)КСНУМКС к КСНУМКС к КСНУМКСмм (КСНУМКС к КСНУМКС к КСНУМКС инча)
Отварање вилице1.25 инча
Безбедносне оценеEN 61010, CAT III, UL approved, CE marked

Гаранција и подршка

For warranty information, technical support, or service inquiries, please refer to the official AEMC Instruments webсајт или контактирајте њихову службу за кориснике. Сачувајте рачун за куповину за потребе гаранције.

© AEMC Instruments. All rights reserved.

Овај приручник се може променити без најаве.