The AC Infinity CLOUDPLATE T7-N is an intelligent fan system specifically designed for cooling audio video, DJ, server, network, and IT equipment racks. Maintaining an optimal temperature for rack-mount equipment is crucial to prevent overheating, ensure consistent performance, and extend their operational lifespan. This manual provides essential information for the proper setup, operation, and maintenance of your CLOUDPLATE T7-N unit.
Безбедносне информације
- Уверите се да је напајање волtage matches the requirements specified for the unit.
- Do not operate the unit with damaged cords or plugs.
- Држите уређај даље од воде или прекомерне влаге.
- Do not block the fan intake or exhaust vents.
- Увек искључите напајање пре него што извршите било какво одржавање или инсталацију.
Садржај пакета
The complete kit includes the following items:
- 1 x CLOUDPLATE T7-N 2U Fan Unit
- 1 x Corded 6-ft Thermal Probe
- 1 x Упутство за употребу (овај документ)
- Rack Mount Screws
- Цаге Нутс
- 1 x Corded 6-ft Power Supply

Image: Included accessories for the CLOUDPLATE T7-N, showing the thermal probe, power adapter, and mounting screws.
Производ је завршенview
The CLOUDPLATE T7-N is housed in a solid anodized aluminum construction, occupying two rack units (2U) of space. It features CNC-machined detailing for a professional appearance. This model is designed for intake airflow, drawing cooler air into the rack, and should typically be positioned near the bottom.
The unit incorporates four custom-engineered dual-ball bearing fans, rated for 67,000 hours of operation and certified by CE and RoHS. These fans utilize a PWM motor and spiral-curved blade design to maximize airflow at lower speeds while minimizing noise levels.

Слика: Детаљна view of a dual-ball bearing fan with PWM motor, designed for high performance and minimal noise.
Сетуп
- Монтажа на рацк: Identify a 2U space in your 19-inch equipment rack. Use the provided rack mount screws and cage nuts to securely install the CLOUDPLATE T7-N unit. Ensure the unit is flush with the rack rails.
- Thermal Probe Connection: Connect the corded 6-ft thermal probe to the designated port on the unit. Position the probe within the rack where you want to monitor the temperature, typically near heat-generating equipment.
- Прикључак за напајање: Connect the provided 6-ft power supply to the unit and then to a standard electrical outlet.
- Почетно укључивање: Once all connections are secure, the unit will power on, and the LCD display will activate.

Image: The CLOUDPLATE T7-N unit seamlessly integrated into a standard equipment rack.

Image: Illustrates the intake airflow design, with cool air entering from the bottom and warm air exiting the top of the rack.
Упутство за употребу
The CLOUDPLATE T7-N features an LCD digital controller with a programmable thermostat and automated speed control. This allows the system to react to varying temperatures efficiently.
- СМАРТ режим: This mode automatically adjusts the fan speed based on the temperature detected by the thermal probe. You can set a target temperature and a buffer, and the fans will increase speed as the temperature rises above the target plus buffer.
- Ручни режим: Manually select one of six available fan speeds to maintain a constant airflow, regardless of temperature.
- Температурни аларми: The controller can be set to trigger alarm warnings if the temperature exceeds a user-defined threshold.
- Fan Failure Triggers: The system monitors fan operation and can alert you in case of a fan failure.
- Подешавања екрана: Adjust screen brightness with three available settings. The display also features a lock function to prevent accidental changes.
- Резервна меморија: Settings are saved even if power is interrupted.
- Порт за проширење: An expansion port at the rear allows for daisy-chaining additional CLOUDPLATE units or AC Infinity rack roof dual-fan kits to share the same control programming for enhanced cooling.

Image: The intelligent programming display showing current temperature, set temperature, fan speed, and buffer settings.
Video: An official product video demonstrating the features and functionality of the CLOUDPLATE Series rack mount cooling fan systems.
Одржавање
Regular maintenance ensures optimal performance and longevity of your CLOUDPLATE T7-N unit.
- Чишћење: Periodically inspect the fan grilles and blades for dust accumulation. Use a soft brush or compressed air to gently clean the fans and vents. Ensure the unit is powered off and unplugged before cleaning.
- Thermal Probe: Keep the thermal probe clean and free from obstructions to ensure accurate temperature readings.
- Везе: Periodically check all cable connections (power, thermal probe, expansion) to ensure they are secure.
Решавање проблема
| Проблем | Могући узрок | Решење |
|---|---|---|
| Fans not spinning / Display off | No power, loose connection, power adapter issue. | Check power cable connection to unit and outlet. Ensure outlet is functional. Try a different power adapter if available. |
| Нетачно очитавање температуре | Thermal probe improperly placed or damaged. | Ensure thermal probe is securely connected and positioned correctly. Avoid placing it directly on hot components. Check for physical damage to the probe. |
| Fans running too fast/slow in SMART mode | Incorrect temperature settings (SET, BUFFER). | Adjust the SET temperature and BUFFER values on the controller to match your desired cooling profile. |
| Јединица је бучна | High fan speed, dust accumulation, fan bearing issue. | Lower the fan speed setting. Clean the fan blades and grilles. If noise persists at low speeds, contact support. |
| Alarm warning displayed | Temperature exceeded alarm threshold, fan failure. | Check the current temperature. If it's too high, increase fan speed or check for obstructions. If it's a fan failure warning, inspect fans for operation. |
Спецификације
| Феатуре | Детаљ |
|---|---|
| Модел | AI-CP2H |
| Рацк Спаце | 2U |
| Дизајн | Интаке |
| Тотал Аирфлов | 50 до 220 ЦФМ |
| Тотал Ноисе | 10 до 36 дБА |
| Статички притисак | 2.56 мм-Х2О |
| Оператинг Волtage | 12В ДЦ |
| Повер | 10 В |
| Цуррент | 0.83 А |
| Улаз за зидни адаптер | 100 до 240В АЦ |
| Радна влажност | 35 до 85% РХ |
| Радна температура | 0 до 158°Ф (0 до 70°Ц) |
| Вентилаторски лежајеви | Дуал Балл |
| L10 Life Expectancy | 67,000 сата |
| Укупне димензије | 19.0 к 3.5 к 1.5 инча (48.3 к 8.9 к 3.8 цм) |
| Материјал | Алуминијум |

Image: Visual representation of the unit's dimensions and core performance specifications.