This manual provides essential instructions for the safe and efficient use of your Techly Professional 023189 Vertical Rack Power Strip. Please read this manual thoroughly before installation and operation, and retain it for future reference.
The Techly Professional 023189 is a 12-outlet vertical rack-mountable power distribution unit (PDU) designed for professional environments. It features Schuko outlets, a thermal-magnetic circuit breaker for overload protection, and a durable aluminum and black finish.
Безбедносне информације
WARNING: To reduce the risk of electric shock, fire, or injury, always follow basic safety precautions when using electrical products.
- Do not exceed the maximum load capacity of 3.5 kW (16 A, 250 V AC).
- Овај производ је дизајниран само за унутрашњу употребу.
- Do not connect multiple power strips together.
- Уверите се да је продужни кабл правилно уземљен.
- Do not open or modify the device. Refer all servicing to qualified personnel.
- Држати даље од воде и окружења са високом влажношћу.
- Ensure proper ventilation when installed in a rack.
Садржај пакета
Проверите да ли су сви предмети присутни и да нису оштећени:
- Techly Professional 023189 Vertical Rack Power Strip (12 Schuko outlets)
- Упутство за употребу
Image: The product packaging box, labeled "TECHLY PROFESSIONAL 19" Power Distribution Unit".
Производ је завршенview
The Techly Professional 023189 is a robust power distribution unit designed for vertical mounting in 19-inch server racks. It provides 12 Schuko outlets for connecting various electrical devices.
Слика: Пуна view of the Techly Professional 023189 power strip, showing 12 Schuko outlets, the circuit breaker, and mounting brackets.
Кључне карактеристике:
- 12 Schuko (IEC60884) outlets angled at 45°
- Integrated thermal-magnetic circuit breaker for overload protection
- Vertical rack-mountable design
- 3-meter power cable with angled Schuko plug
- Durable aluminum and black finish
- Maximum load capacity: 3.5 kW (16 A, 250 V AC)
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in an open position, revealing the blue switch and "I ON / O OFF" markings.
Слика: Детаљна view of the angled Schuko power plug, which connects the power strip to the main power source.
Подешавање и инсталација
- Распакујте продужну траку: Carefully remove the power strip from its packaging. Inspect for any signs of damage.
- Изаберите локацију за монтажу: Select a suitable vertical location within a standard 19-inch server rack. Ensure there is adequate space for cable management and ventilation.
- Mount the Power Strip: Use appropriate rack screws (not included) to securely fasten the power strip's mounting brackets to the rack rails.
- Повежите се на извор напајања: Plug the power strip's angled Schuko plug into a properly grounded wall outlet or UPS.
- Повежите уређаје: Plug your electrical devices into the 12 Schuko outlets on the power strip. Ensure the total power consumption does not exceed 3.5 kW.
Image: A partial view of the power strip, highlighting the mounting brackets on the side, designed for vertical installation in a server rack.
Операција
- Укључено: Locate the thermal-magnetic circuit breaker on the power strip. Flip the switch to the "I ON" position to supply power to the outlets.
- Заштита од преоптерећења: If the total current drawn by connected devices exceeds 16 A, the thermal-magnetic circuit breaker will automatically trip to the "O OFF" position, cutting power to prevent damage.
- Искључивање: To cut power to all connected devices, flip the circuit breaker switch to the "O OFF" position.
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in a closed position, covering the blue switch.
Одржавање
- Чишћење: Disconnect the power strip from the main power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- инспекција: Periodically inspect the power strip, cable, and plug for any signs of wear, damage, or overheating. If any damage is observed, discontinue use immediately and replace the unit.
- вентилација: Ensure that the power strip and connected devices have adequate airflow to prevent overheating.
Решавање проблема
| Проблем | Могући узрок | Решење |
|---|---|---|
| Нема струје у утичницама. | Прекинуо се прекидач. | Reduce the load by unplugging some devices, then reset the circuit breaker by flipping it to "I ON". |
| Нема струје у утичницама. | Продужни кабл није укључен. | Ensure the power strip's plug is securely inserted into a live wall outlet. |
| Devices not functioning. | Device-specific issue. | Check the individual device's power connection and functionality. |
Ако проблем и даље постоји након покушаја ових решења, обратите се корисничкој подршци.
Спецификације
- Модел: I-CASE STRIP-12SH
- Бренд: Techly Professional
- Продајна места: 12 x Schuko (Type F) 45° angled with earth
- Улазни утикач: Angled Schuko (Type F)
- Кабл: Х05ВВ-Ф 3Г 2.5 мм²
- Дужина кабла: 3 метара
- Електрична оцена: 16А, 250ВАЦ
- Максимални капацитет оптерећења: 3.5 кВ
- Димензије (Д к Ш к В): 735 x 62 x 44 mm (73.5L x 6.2W cm)
- Тежина: 1795 грама
- Материјал: Aluminum (body), Black (finish)
- Посебна карактеристика: Mountable (vertical rack installation)
- Сертификати: ЦЕ, ВЕЕЕ
Информације о гаранцији
Information regarding specific warranty terms is not available in the provided product details. Please refer to the retailer's return policy or contact Techly Professional directly for warranty details.
Политика враћања: The buybox winner indicates a 30-day return policy (refund/replacement).
Корисничка подршка
For technical assistance or further inquiries, please visit the official Techly webсајту или контактирајте свог продавца.
Произвођач: TECHLY PROFESSIONAL
Webсајт: ввв.тецхли.цом (Hypothetical link, as not provided in JSON)