Елитецх РЦ-4ХЦ

Упутство за употребу Elitech RC-4HC USB регистратора података о температури и влажности

Model: RC-4HC

1. Производ је готовview

The Elitech RC-4HC is a USB temperature and humidity data logger designed for monitoring and recording environmental conditions. It features an internal temperature and humidity sensor, with an option for an external temperature sensor. The device has a large storage capacity and allows for data export via USB.

Elitech RC-4HC USB Temperature and Humidity Data Logger with packaging

Image 1: Elitech RC-4HC USB Temperature and Humidity Data Logger with its packaging, showing the device and the '50 PACK' label.

2. Садржај пакета

Уверите се да су све ставке присутне у пакету:

  • 1 x RC-4HC Data Logger
  • 1 к спољни сензор температуре
  • 1 к УСБ кабл
  • 1 к Упутство за употребу
  • 1 x Validation Certificate
  • 1 x Lithium Metal Battery
Elitech RC-4HC package contents

Image 2: Contents of the Elitech RC-4HC package, including the data logger, external sensor, USB cable, user manual, certificate, and battery.

3. Подешавање и инсталација

3.1 Инсталација батерије

Before initial use, install the included Lithium Metal battery.

  1. Locate the battery compartment on the back of the data logger.
  2. Користите новчић или сличан алат да окренете поклопац батерије у смеру супротном од казаљке на сату да бисте га отворили.
  3. Place the battery under the small metal clip with the positive pole (+) facing you.
  4. Вратите поклопац батерије и окрените га у смеру казаљке на сату да бисте га причврстили.
Steps for battery installation in Elitech RC-4HC

Image 3: A four-step visual guide demonstrating how to correctly install the battery into the Elitech RC-4HC data logger, showing the positive terminal placement.

3.2 External Sensor Connection (Optional)

If external temperature monitoring is required, connect the external temperature sensor to the designated port on the data logger.

Elitech RC-4HC connected to USB and external sensor

Image 4: The Elitech RC-4HC data logger connected to a computer via USB and also showing the external temperature sensor connected.

3.3 Software Installation and Initial Parameter Setup

To configure the data logger and retrieve data, install the ElitechLog software on your computer (compatible with MAC/WIN). The software allows you to set logging parameters such as interval (e.g., 10 seconds), alarm limits, and temperature units (e.g., ℃ or ℉).

ElitechLog software workflow for data logger setup

Image 5: A flowchart illustrating the workflow for setting up the data logger using ElitechLog software on both Windows and Mac operating systems, from connecting the device to saving parameters and starting recording.

Video: Elitech RC-4HC USB Temperature and Humidity Data Logger How to Use

4. Упутство за употребу

4.1 Starting Data Logging

After setting parameters via the software, disconnect the logger from the computer. To start logging, press and hold the button on the logger for more than 4 seconds. A triangle sign firmly lit up on the screen indicates that logging has started.

4.2 Viewing Current Data

Press the button once to light up the screen and view the current temperature. Press again to cycle through humidity, total logged points, time, date, maximum temperature, minimum temperature, and upper/lower temperature limits.

4.3 Data Retrieval and Export

Connect the data logger to your computer using the USB cable. Open the ElitechLog software. The software will automatically read the recorded data. You can then view the data in graph or list format and export it to PDF or Excel files. The software also supports managing and comparing multiple historical data sets.

Elitech RC-4HC data export via software

Image 6: An illustration showing the Elitech RC-4HC data logger connected to a computer, with data being exported to various formats like PDF, Word, Excel, and TXT via ElitechLog software.

5. Features and Specifications

  • Сензори: Internal 1 temperature sensor and 1 humidity sensor, 1 optional external temperature sensor.
  • Температурни опсег: -40℃ to +85℃ (-22℉ to 185℉).
  • Опсег влажности: 10% до 99% РХ.
  • Прецизност температуре: ±0.5℃/±0.9℉ (-20℃ to +40℃); ±1℃/±1.8℉ (others).
  • Резолуција: 0.1℃/℉.
  • Тачке података: 16,000.
  • Интервал дневника: Подесиво од 10 секунди до 24 сати.
  • Јединица температуре: Selectable between ℉ and ℃.
  • Аларм: LCD alarm indication, buzzer alarm.
  • Повезивање: USB for PC connection.
  • Извоз података: PDF/EXCEL via data management software.
  • батерија: 1 Lithium Metal battery (included).
  • Димензије: Width: 44mm, Height: 84mm, Thickness: 20mm.
Elitech RC-4HC specifications

Image 7: A visual representation of the Elitech RC-4HC data logger's key specifications, including temperature and humidity measurement ranges, accuracy, resolution, and data capacity.

Elitech RC-4HC dimensions and buzzer alarm

Image 8: The Elitech RC-4HC data logger showing its dimensions (width 44mm, height 84mm, thickness 20mm) and highlighting the buzzer alarm feature.

6. Одржавање

To ensure optimal performance and longevity of your Elitech RC-4HC data logger:

  • Чишћење: Wipe the device clean with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • Замена батерије: Replace the Lithium Metal battery when the low battery indicator appears on the display.
  • Складиштење: Уређај чувајте на хладном и сувом месту, даље од директне сунчеве светлости и екстремних температура када се не користи дуже време.

КСНУМКС. Решавање проблема

If you encounter issues with your Elitech RC-4HC data logger, consider the following:

  • Device Not Starting: Ensure the battery is correctly installed with the positive pole facing up and is not depleted.
  • No Data on Software: Verify the USB connection to the computer. Ensure the ElitechLog software is running and the device is recognized.
  • Нетачна очитавања: Check if the external sensor is properly connected (if used). Ensure the device is placed in an environment suitable for its operating range.
  • Проблеми са софтвером: Ensure you have the latest version of ElitechLog software installed. Refer to the software's help documentation for specific error messages.

8. Гаранција и подршка

For warranty information, technical support, or service inquiries, please contact Elitech Technology Inc. using the details below: