Edgecore Networks AS7326-56X

Edge-Core Networks AS7326-56X Switch User Manual

Model: AS7326-56X

1. Увод

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the Edge-Core Networks AS7326-56X switch. The AS7326-56X is a high-performance network switch designed for data center and enterprise environments, featuring 48 x 25 Gigabit Ethernet SFP28 ports and 8 x 100 Gigabit Ethernet QSFP+ uplink ports. It supports the Open Network Install Environment (ONIE) for flexible operating system deployment.

2. Безбедносне информације

Придржавајте се следећих мера безбедности како бисте спречили повреде и оштећења опреме:

  • Ensure proper grounding of the device before connecting power.
  • Use only the power cord supplied with the unit or a certified equivalent.
  • Не користите прекидач у окружењима са прекомерном влагом или екстремним температурама.
  • Избегавајте блокирање вентилационих отвора да бисте спречили прегревање.
  • Disconnect all power before performing any maintenance or installation procedures.
  • Само квалификовано особље треба да инсталира и сервисира ову опрему.

3. Садржај пакета

Проверите да ли су све ставке присутне у пакету:

  • Edge-Core Networks AS7326-56X Switch Unit
  • AC Power Cord(s)
  • Rack Mounting Kit (brackets, screws)
  • Кабл за конзолу (РЈ-45 до ДБ-9)
  • Документација (Кратки водич, Безбедносне информације)

4. Физички опис

The AS7326-56X switch features a standard 1U rack-mountable form factor. The rear panel provides access to power inputs, fan modules, and network ports.

Позади view of the Edge-Core Networks AS7326-56X switch showing power inputs, fan modules, and network ports.

Слика 1: Позади view of the Edge-Core Networks AS7326-56X switch. This image displays the back panel of the switch, featuring two power supply units on the left and right sides, each with an orange handle. In the center, there are multiple fan modules, also with orange handles, arranged horizontally. Between the power supplies and fan modules, and to the right of the fan modules, are the various network port interfaces, including 48 x 25G SFP28 ports and 8 x 100G QSFP+ uplink ports, designed for high-speed network connectivity.

4.1. Предњи панел

The front panel typically includes status LEDs for power, system, and individual port activity. Specific LED indicators and their meanings are detailed in the LED Status section.

4.2. Задња плоча

The rear panel (as shown in Figure 1) houses the following components:

  • Power Supply Units (PSUs): Redundant, hot-swappable AC power supply modules.
  • Модули вентилатора: Hot-swappable fan modules for cooling.
  • 48 x 25G SFP28 Ports: For high-speed server and access layer connectivity.
  • 8 x 100G QSFP+ Uplink Ports: For high-bandwidth uplinks to core network devices.
  • Порт за конзолу: RJ-45 serial port for local management access.
  • Порт за управљање: RJ-45 Ethernet port for out-of-band management.
  • УСБ порт: For software upgrades or configuration backup/restore.

5. Подешавање

5.1. Рацк Моунтинг

  1. Attach the provided rack-mount brackets to the sides of the switch using the included screws.
  2. Secure the switch into a standard 19-inch equipment rack using appropriate rack screws. Ensure adequate space for airflow around the unit.

5.2. Прикључак за напајање

  1. Connect the AC power cord(s) to the power input receptacles on the rear panel of the switch.
  2. Plug the other end of the power cord(s) into a grounded AC power outlet.
  3. The switch will power on automatically once connected to power.

5.3. Мрежне везе

  • SFP28 портови: Insert compatible 25G SFP28 transceivers into the 48 SFP28 ports and connect fiber optic cables to your network devices.
  • QSFP+ Ports: Insert compatible 100G QSFP+ transceivers into the 8 QSFP+ ports and connect fiber optic cables for uplink connections.

5.4. Initial Configuration Access

  1. Connect a computer to the console port using the provided RJ-45 to DB-9 console cable.
  2. Configure your terminal emulation software (e.g., PuTTY, Tera Term) with the following settings: 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control.
  3. Power on the switch. The boot process will display on the console.
  4. Alternatively, connect an Ethernet cable from your management workstation to the dedicated management port and configure an IP address within the same subnet as the switch's default management IP (if applicable).

6. Упутство за употребу

6.1. Power On and Boot Sequence

Upon connecting power, the switch will initiate its boot sequence. Observe the system LEDs for status indications. The ONIE (Open Network Install Environment) will load, allowing for the installation of a network operating system (NOS).

6.2. ЛЕД индикатори статуса

Refer to the following table for common LED indicators:

ЛЕДБоја/СтањеОпис
СистемЗелена (чврста)Систем ради нормално.
Системћилибар (чврсто)System fault or warning.
ПоверЗелена (чврста)Power supply is active.
Веза/активностЗелена (чврста)Port link established.
Веза/активностЗелена (трепери)Лучка делатност.

6.3. ONIE and Network Operating System (NOS)

The AS7326-56X ships with ONIE pre-installed. ONIE is a small operating system that provides an environment for installing other network operating systems. To install a NOS:

  1. Access the ONIE prompt via the console port.
  2. Follow the specific instructions provided by your chosen NOS vendor for installation via ONIE (e.g., using HTTP, FTP, or local USB).
  3. Once the NOS is installed, the switch will reboot into the new operating system.

7. Одржавање

7.1. Чишћење

Periodically clean the exterior of the switch with a soft, dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid or aerosol cleaners directly on the unit.

7.2. Ажурирања фирмвера и софтвера

Regularly check the Edge-Core Networks support website or your NOS vendor's website for the latest firmware and software updates. Follow the provided instructions for updating to ensure optimal performance and security.

7.3. Fan and Power Supply Replacement

The fan modules and power supply units are hot-swappable. To replace a module:

  1. Grasp the handle of the module to be replaced.
  2. Gently pull the module straight out of its bay.
  3. Insert the new module into the empty bay, ensuring it is fully seated.

КСНУМКС. Решавање проблема

8.1. Нема снаге

  • Verify that the power cord(s) are securely connected to both the switch and the power outlet.
  • Проверите да ли је утичница функционална тако што ћете је тестирати са другим уређајем.
  • Check the power supply unit LEDs. If off, the PSU may be faulty or not receiving power.

8.2. No Link on Port

  • Check the cable connection between the switch port and the connected device.
  • Ensure the correct transceiver type (SFP28/QSFP+) is used and properly seated.
  • Verify that the connected device is powered on and its port is active.
  • Check the port configuration on both the switch and the connected device (speed, duplex, VLANs).

8.3. Console Access Issues

  • Confirm the console cable is correctly connected.
  • Verify the terminal emulation software settings (115200 baud, 8 data bits, no parity, 1 stop bit, no flow control).
  • Try a different console cable or USB-to-serial adapter.

9. Спецификације

ФеатуреОпис
МоделАС7326-56Кс
Портс48 x 25G SFP28, 8 x 100G QSFP+
Димензије (ДкШкВ)18 к 19 к 2 инча
Тежина21 лбс
Тип интерфејсаСФП, СФП+
Компатибилни уређајиDesktop (Note: Primarily designed for rackmount environments)
ПроизвођачEdge-Core Networks
УПЦ662698610482
Фирст Аваилабле1. октобра 2019. године

10. Информације о гаранцији

The Edge-Core Networks AS7326-56X switch comes with a 3 година гаранције from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For detailed warranty terms and conditions, please refer to the official Edge-Core Networks warranty policy available on their webсајту или контактирајте њихов тим за подршку.

11. Техничка подршка

For technical assistance, product inquiries, or to report issues, please contact Edge-Core Networks technical support. Before contacting support, ensure you have the product model number (AS7326-56X) and serial number readily available.

Visit the official Edge-Core Networks webсајт за ресурсе подршке, честа питања и контакт информације: ввв.едге-цоре.цом

© 2023 Edge-Core Networks. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.