Производ је завршенview
The Bluex Bulbs MP100/U/MED is a 100-watt Metal Halide ED17 bulb designed for high-intensity discharge (HID) lighting applications. This bulb features a medium E26 base and provides 8500 lumens of 4000K white light. It is suitable for outdoor lighting and commercial interiors, offering high efficacy and a long service life. This product comes in a pack of three bulbs.

Image: Three Bluex Bulbs MP100/U/MED 100 Watt Metal Halide ED17 Bulbs, clear glass with internal arc tube and medium screw base.
Важне информације о безбедности
WARNING: THIS IS A NON SELF-EXTINGUISHING TYPE R LAMP
Ово лamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain types of lamps will automatically extinguish when the outer envelope is broken or punctured are commercially available.
Complies with USA Federal standard 21 CFR 1040.30.
Опште мере предострожности:
- Operate with Compatible Ballast and Fixture: Ово лamp must be operated in a fixture with a ballast which has an ANSI designation identical to that found on the lamp's outer glass bulb. Otherwise, the lamp may rupture, resulting in the discharge of hot particles. Failure to follow these instructions may result in PROPERTY DAMAGE or PERSONAL INJURY.
- Electrical Shock and Burn Hazard: Немојте уклањати или уметати лamp while power is on. Immediately shut off power and allow the lamp да се потпуно охлади пре руковања.
- Упутство за инсталацију и рад:
- A specially designed socket which is electrically rated to withstand a 4000 volt pulse is required for all High Intensity Discharge lamps except for the 750 and 1000 watt lamp which require a socket rated to withstand a 5000 volt pulse.
- To avoid injury, allow bulb to cool before removing from fixture.
- Screw in bulb firmly but do not force into fixture to avoid breakage.
- Do not install into a regular socket.
- This bulb may be operated in any position.
- Правилна нега и одржавање: To reduce the possibility of rupture and premature failure,
- Do not use with luminaries which would cause an excessive increase in arc-tube operating voltage.
- Do not expose operating bulb to moisture.
- Replace bulb if outer glass bulb has been scratched or damaged in any way.
- Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition.
⚠ WARNING: Birth Defects and/or Reproductive Harm - ввв.П65Варнингс.ца.гов

Image: Warning label detailing safety information for Type R lamps, including risks of UV radiation and operational precautions.
Упутство за инсталацију
- Ensure the power supply to the fixture is turned OFF at the circuit breaker before beginning installation.
- Allow the existing bulb (if any) and fixture to cool completely before handling.
- Carefully remove the old bulb by unscrewing it counter-clockwise from the socket.
- Inspect the fixture and socket for any damage or wear. Ensure the socket is rated for HID lamps and can withstand a 4000 volt pulse.
- Gently screw the Bluex Bulbs MP100/U/MED into the E26 medium base socket by turning it clockwise until it is firmly seated. Do not overtighten or force the bulb.
- Ensure the bulb is properly aligned and not loose in the socket.
- Restore power to the fixture at the circuit breaker.
- Укључите прекидач за светло да бисте проверили исправан рад.
Напомена: This bulb requires a compatible M90/O ballast for proper operation. Verify your fixture's ballast compatibility before installation.
Упутство за употребу
Once properly installed in a compatible fixture with the correct ballast, the Bluex Bulbs MP100/U/MED metal halide bulb operates by simply turning on the power supply to the fixture. Allow a brief warm-up period for the bulb to reach full brightness. Metal halide lamps require a cool-down period before they can be re-ignited after being turned off.
Key Operating Characteristics:
- Време загревања: Metal halide bulbs require a few minutes to reach full light output and color stability after ignition.
- Време поновног удара: If the bulb is turned off, it must cool down for several minutes before it can be re-ignited. Attempting to re-ignite a hot bulb immediately may prevent it from starting or reduce its lifespan.
- Без затамњивања: This bulb is not dimmable and should not be used with dimmer switches.
Одржавање
- Чишћење: Пре чишћења проверите да ли је напајање искључено и да ли се сијалица охладила. Нежно обришите спољашњу стаклену кућиште чистом, сувом крпом која не оставља влакна. Не користите течна средства за чишћење или абразивне материјале.
- инспекција: Periodically inspect the bulb for any signs of damage, such as scratches, cracks, or discoloration on the outer glass. Replace any damaged bulbs immediately.
- Одржавање уређаја: Regularly check the fixture for dust, debris, or corrosion, which can affect performance and safety.
- Замена: Replace the bulb when it reaches the end of its rated lifespan (approximately 15,000 hours) or if it exhibits signs of failure, such as flickering, reduced brightness, or failure to ignite. Always replace with a bulb of the same type and wattage.
Решавање проблема
| Проблем | Могући узрок | Решење |
|---|---|---|
| Сијалица не светли. | No power to fixture; Incorrectly installed bulb; Incompatible ballast; Faulty bulb; Faulty fixture/socket. | Check power supply and circuit breaker. Ensure bulb is screwed in firmly. Verify ballast compatibility (M90/O). Replace bulb if necessary. Inspect fixture wiring and socket. |
| Сијалица трепери или се циклично пали/гаси. | Bulb nearing end of life; Incorrect ballast; Voltagе флуктуације. | Replace bulb. Ensure ballast is correct for the bulb. Consult an electrician for voltagе питања. |
| Смањена осветљеност. | Прашина/прљавштина на сијалици; Сијалица се ближи крају животног века. | Clean the bulb (when cool and power off). Replace bulb. |
| Bulb takes a long time to ignite or re-ignite. | Normal warm-up/restrike time; Bulb nearing end of life. | Allow normal warm-up/restrike period. If excessive, replace bulb. |
Спецификације
- Бренд: Блуек сијалице
- Модел: MP100/U/MED
- Тип светла: Метал Халиде
- Ватtage: 100 Ваттс
- Величина облика сијалице: ЕД17
- База сијалице: Е26 Средњи
- Осветљеност: 8500 лумена
- Температура боје: 4000 Келвина (бела светлост)
- ANSI Code: М90/О
- Посебна карактеристика: Нот Диммабле
- Просечан животни век: 15,000 сата
- Унутрашња/спољна употреба: Оутдоор
- Материјал: стакло
- Тежина артикла: Приближно 14.4 унци (0.41 кг)
- Димензије пакета: 8.54 к 7.17 к 3.23 инча
Гаранција и подршка
For warranty information or technical support regarding your Bluex Bulbs MP100/U/MED Metal Halide ED17 Bulb, please contact Bluex Bulbs customer service. Refer to the product packaging or the official Bluex Bulbs webсајт за најновије контакт податке и услове гаранције.
Произвођач: Блуек сијалице
Датум прве доступности: 25. новембар 2019