Важне информације о безбедности
- Пажљиво прочитајте сва упутства пре употребе уређаја.
- Сачувајте ово упутство за будућу употребу.
- Do not expose the camera to moisture or extreme temperatures.
- Use only the power adapter specified for this device.
- Не покушавајте да растављате или модификујете камеру. Сва сервисирања препустите квалификованом особљу.
- Ensure proper ventilation around the camera during operation.
Садржај пакета
Проверите да ли су све ставке присутне у пакету:
- AIDA HD-NDI-Cube Camera
- Power Adapter (typically included for operation)
- Документација (овај приручник)
- Note: The product listing generically mentions "item" for 'whats_in_the_box'. This manual assumes the camera unit and necessary power supply are included.
Сетуп
1. Физичка инсталација
The AIDA HD-NDI-Cube camera features versatile mounting options for various applications.
- Identify a suitable location for the camera, ensuring it is stable and has clear line of sight for its intended use.
- Utilize the top and bottom tripod mounts for secure attachment to tripods, stands, or other mounting hardware.
- Ensure adequate space for cable connections and ventilation.

Слика 1: Страна view of the AIDA HD-NDI-Cube camera, showing its compact form factor.
2. Повезивање
Connect the camera to power and network for operation.
- Прикључак за напајање: Connect the provided 12V DC power adapter to the "12VDC" port on the rear of the camera. Plug the adapter into a suitable power outlet. The power indicator LED should illuminate.
- Мрежна конекција: Connect an Ethernet cable from your network switch or router to the "IP/NDI|HX" Ethernet port on the rear of the camera. This connection is essential for NDI|HX video streaming and IP control.
- Инсталација сочива: If a C/CS mount lens is not pre-installed, carefully attach your desired C/CS mount lens to the camera body. Ensure it is securely fastened.

Figure 2: Rear panel of the AIDA HD-NDI-Cube, showing the IP/NDI|HX Ethernet port and 12VDC power input.

Слика 3: Предња и бочна страна view of the AIDA HD-NDI-Cube camera, highlighting the C/CS lens mount and SVC port.
Упутство за употребу
1. Прво укључивање
Once connected to power and network, the camera will initiate its startup sequence. The power indicator LED will confirm the device is on.
2. Приступ Web UI
The camera features an accessible web user interface (UI) for configuration and control.
- Уверите се да је ваш рачунар на истој мрежи као и камера.
- Use a network scanner tool (e.g., NewTek NDI Tools) to discover the camera's IP address on your network.
- Отвори а web browser and enter the camera's IP address into the address bar.
- Log in using the default credentials (refer to the camera's specific documentation for default username/password, typically "admin" / "admin" or similar).
- Фром тхе web UI, you can adjust image parameters, network settings, and stream directly to social media platforms.
3. NDI|HX Video Streaming
The AIDA HD-NDI-Cube outputs Full HD 1080p60 NDI|HX video, compatible with NDI-enabled software and hardware.
- Once the camera is connected to the network, it should be discoverable by NDI-compatible applications (e.g., OBS Studio, vMix, TriCaster).
- In your NDI receiving software, select the AIDA HD-NDI-Cube as an NDI source.
- Adjust video settings within your software or the camera's web UI as needed for optimal performance.
Одржавање
1. Чишћење
- Ensure the camera is powered off and disconnected from all sources before cleaning.
- Use a soft, dry cloth to wipe the camera body. Do not use liquid cleaners or aerosols.
- За сочиво користите специјализовану крпу и раствор за чишћење сочива како бисте избегли огреботине.
2. Ажурирања фирмвера
Periodically check the AIDA Imaging official website for available firmware updates. Firmware updates can improve performance, add features, and resolve issues.
- Download the latest firmware from the manufacturer's support page.
- Follow the specific instructions provided with the firmware update package for installation via the camera's web УИ.
- Опрез: Do not power off the camera during a firmware update, as this may cause irreversible damage.
Решавање проблема
No NDI Signal Detected
- Мрежна конекција: Ensure the Ethernet cable is securely connected to both the camera and the network switch/router. Verify network activity lights on the camera's Ethernet port.
- ИП адреса: Confirm that the camera and the receiving computer are on the same IP subnet. Incorrect subnet masks can prevent NDI discovery. Access the camera's web UI to verify or adjust network settings. A firmware update may be required to resolve specific IP addressing issues.
- Software Permissions: If using software like OBS Studio on Windows, ensure the application is run with administrator privileges. Some NDI implementations require elevated permissions to access network streams.
- Подешавања заштитног зида: Check firewall settings on your computer and network to ensure NDI traffic is not being blocked.
Повремени губитак сигнала
- Стабилност мреже: Verify the stability and bandwidth of your network. NDI|HX requires a stable network connection.
- Интегритет кабла: Inspect Ethernet cables for damage. Try replacing cables if issues persist.
- Фирмвер: Ensure the camera's firmware is up to date. Older firmware versions may have known stability issues.
Лош квалитет слике
- Lens Focus: Adjust the focus of the C/CS mount lens.
- Услови осветљења: Ensure adequate and appropriate lighting for your scene.
- Web Подешавања корисничког интерфејса: Приступите камери web UI to adjust image parameters such as exposure, white balance, and color temperature.
- Дигитални зум: Avoid excessive digital zoom, as it can degrade image quality on 1080p cameras. Consider variable focus lens replacements for optical zoom capabilities.
Техничке спецификације
| Феатуре | Спецификација |
|---|---|
| Бранд | АИДА Имагинг |
| Број модела | ХД-НДИ-ЦУБЕ |
| Тип сензора | 1/3'' Progressive Scan CMOS |
| Резолуција снимања видео записа | 1080p (Full HD) |
| Ефективна видео резолуција | 2.07 МП |
| Технологија повезивања | Ethernet (NDI|HX) |
| Монтажа за објектив | Ц/ЦС носач |
| Минимална жижна даљина | 1 Millimeter (Lens dependent) |
| Максимална жижна даљина | 4 Millimeters (Lens dependent) |
| Максимални отвор бленде | 3 f (Lens dependent) |
| Фоцус Типе | Fixed Focus (Lens dependent) |
| Форм Фацтор | Цомпацт |
| Боја | Црно |
| Карактеристике | Low Light Capability |
| Стабилизација слике | бр |
| Ниво отпорности на воду | Није водоотпоран |
| Подржани аудио формат | ПЦМ, МП3, ААЦ |
| Формат видео снимања | АСФ |
| Подржани формат слике | ЈПЕГ |
| Омјер слике | 16:9 |
| Поставке баланса белог | Ауто |
| Тип контроле експозиције | Програм (П) |
| Режими снимања | Manual, Automatic, Program (P) |
| Компатибилни уређаји | ПЦ или Мац |
| УПЦ | 686091739809 |
Гаранција и подршка
Информације о гаранцији
AIDA Imaging products are typically covered by a manufacturer's warranty. For specific warranty terms and conditions, including duration and coverage details, please refer to the warranty card included with your product or visit the official AIDA Imaging webсајту.
Сачувајте доказ о куповини за гаранцијске захтеве.
Корисничка подршка
For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact AIDA Imaging customer support.
- Visit the official AIDA Imaging webсајт за ресурсе подршке, честа питања и контакт информације.
- Have your product model number (HD-NDI-CUBE) and serial number ready when contacting support.