The LARIAU TS58 is a digital insulation resistance tester designed for measuring insulation resistance in various electrical equipment and insulating materials. This includes transformers, motors, cables, switches, and other electrical appliances. It is suitable for maintenance, repair, and testing applications.

This instrument features automatic voltage release, high stability, and reliability. It offers a maximum display count of 2000, 100 groups of data storage, and an insulation resistance measurement range of 0.1 MΩ to 10 GΩ. It also includes AC/DC voltage measurement capabilities and advanced DAR (Dielectric Absorption Ratio) and PI (Polarization Index) measurements for more accurate insulation assessment.

LARIAU TS58 Digital Insulation Resistance Tester front view

Слика 1: Предња страна view of the LARIAU TS58 Digital Insulation Resistance Tester.

2. Безбедносне информације

Please read this manual carefully before using the instrument. Adhere to all safety warnings and operating instructions to prevent electric shock, injury, or damage to the instrument.

  • Always ensure the instrument is in good working condition before use.
  • Observe the high voltage indication on the display, which reminds you of safe operation during measurements.
  • Do not operate the instrument in wet environments or with wet hands.
  • Replace batteries promptly when the low battery indication appears to ensure accurate readings and safe operation.
  • Не покушавајте да мерите волtages or resistances beyond the specified ranges.
  • Ensure proper connection of test leads before initiating any measurement.

3. Производ је готовview

The TS58 features a clear LCD backlit screen for easy reading, a robust dustproof and moisture-proof shell, a foldable bracket for convenient positioning, and comes with a zipper carry bag for portability.

Цлосе-уп views of the TS58 LCD screen, dustproof shell, foldable bracket, and zipper carry bag.

Figure 2: Key features of the TS58, including the LCD screen, protective casing, and accessories.

3.1 Контроле и дисплеј

The device includes a large digital LCD display, function buttons for selecting measurement modes, adjusting output voltage, and initiating tests. It also has input terminals for test leads.

LARIAU TS58 Digital Insulation Resistance Tester highlighting key features like output voltage, measuring ranges, DAR/PI, LCD, data hold, and data storage.

Слика 3: Завршеноview of the TS58's main functions and display elements.

4. Подешавање

4.1 Инсталација батерије

The TS58 is powered by 8 x 1.5V AA/LR6 batteries (not supplied). To install or replace batteries:

  1. Пронађите одељак за батерије на задњој страни инструмента.
  2. Отворите поклопац одељка за батерије.
  3. Insert 8 AA/LR6 batteries, ensuring correct polarity (+/-).
  4. Добро затворите поклопац одељка за батерије.

A low battery indication will appear on the display when batteries need replacement.

5. Упутство за употребу

The TS58 is designed for measuring insulation resistance and AC/DC voltage. Always ensure the test leads are securely connected to the instrument and the circuit under test.

LARIAU TS58 Digital Insulation Resistance Tester with test leads connected, in an electrical testing scenario.

Figure 4: The TS58 tester with test leads, ready for use.

5.1 Мерење изолационог отпора

  1. Connect the test leads to the appropriate terminals on the TS58 and to the equipment under test.
  2. Укључите инструмент.
  3. Use the 'SELECT' button to choose the insulation resistance measurement mode.
  4. Подесите излазну јачину звукаtage (50V/100V/250V/500V/1000V) using the up/down buttons as required for your test.
  5. Press the 'TEST' button to initiate the measurement. The high voltagе индикатор ће засветлети.
  6. Read the insulation resistance value on the LCD screen.
  7. After the test, the instrument automatically discharges the circuit.

5.2 АЦ/ДЦ Волtagе Мерење

  1. Connect the test leads to the appropriate terminals on the TS58 and to the voltagе извор.
  2. Укључите инструмент.
  3. Use the 'SELECT' button to choose the AC or DC voltagе режим мерења.
  4. Прочитајте књtage value on the LCD screen. The measurement range is 10V-600V.

5.3 DAR and PI Index Measurement

The DAR (Dielectric Absorption Ratio) and PI (Polarization Index) measurements help assess the quality and aging status of insulation, mitigating the effects of temperature, humidity, and interference currents.

  1. Perform an insulation resistance test as described in section 5.1.
  2. Press the 'PI/DAR' button. The instrument will automatically compute and display the DAR and PI values.
  3. Refer to industry standards for interpreting DAR and PI values to evaluate insulation condition.

5.4 Чување и опозив података

The TS58 can store up to 100 groups of measurement data.

  • To save data: After a measurement, press the 'HOLD*' button to hold the current reading, then press 'MEM READ' to save it. (Note: The exact sequence might vary; refer to the full manual for precise steps if available).
  • To recall data: Press the 'MEM READ' button and use the up/down arrows to navigate through stored data groups.
LARIAU TS58 Digital Insulation Resistance Tester being used in various electrical testing applications, including wiring, circuit boards, and motor testing.

Figure 5: The TS58 in practical application scenarios.

6. Одржавање

6.1 Чишћење

Wipe the instrument's exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device.

6.2 Складиштење

When not in use for extended periods, remove the batteries to prevent leakage. Store the instrument in its zipper carry bag in a dry environment, away from direct sunlight and extreme temperatures. The recommended storage environment is -10~50℃, <75%RH.

КСНУМКС. Решавање проблема

  • Уређај се не укључује: Проверите да ли су батерије инсталиране и уверите се да нису празне. Замените их ако је потребно.
  • Нетачна очитавања:
    • Ensure test leads are properly connected and not damaged.
    • Verify the correct measurement mode and output voltage are selected.
    • Consider environmental factors like temperature and humidity, especially for insulation resistance measurements.
  • Хигх волtage warning persists after test: The instrument has an automatic voltage release function. If the warning persists, ensure the circuit under test is fully discharged before handling.

8. Спецификације

The following table details the technical specifications of the LARIAU TS58 Digital Insulation Resistance Tester.

Table of specifications for the LARIAU TS58, including dimensions, color, material, screen type, maximum count, output voltage, resistance range, AC/DC voltage range, AC frequency, data storage, short-circuit current, power supply, work environment, and storage environment.

Figure 6: Detailed technical parameters of the TS58.

LARIAU TS58 Technical Specifications
ПараметарВалуе
БојаЦрвена + Сива
МатеријалАБС + силикон
ЕкранЛЦД екран са позадинским осветљењем
Максимални број2000
Оутпут Волtage50V/100V/250V/500V/1000V
Resistance Measuring Range0.1 MΩ ~ 10 GΩ
АЦ/ДЦ Волtagе Мерни опсег10 В-600 В
АЦ Волtagе Фреквенција40-70 Хз
Складиштење података100 група
Кратког споја<1.8 мА
Повер Суппли8 * 1.5 V AA/LR6 (not supplied)
радно окружење0 ~35℃, <75%RH, <2000m
Окружење за складиштење-10~50℃, <75%RH
Величина артикла180 * 140 * 70 мм / 7.09 * 5.51 * 2.76 ин
Тежина ставке (без батерије)623 г / 1.37 лб

9. Гаранција и подршка

Информације о гаранцији производа и корисничкој подршци обично се налазе на паковању производа или на званичном website. Please refer to those resources for details on warranty coverage, technical assistance, and service inquiries.

For further assistance, please contact LARIAU customer support through their official channels.

© 2023 LARIAU. All rights reserved.

Овај приручник је само у информативне сврхе. Спецификације се могу променити без претходне најаве.