JMT HLK-LD2450

JMT HLK-LD2450 24GHz Trajectory Sensor Module User Manual

Model: HLK-LD2450 (F50749)

1. Производ је готовview

The JMT HLK-LD2450 is a 24GHz radar module designed for real-time tracking of moving targets within a detection area. It provides distance, angle, and speed information of these targets via a serial port. This module is primarily intended for indoor applications such as smart homes, offices, and hotels, enabling precise positioning and tracking of people.

JMT HLK-LD2450 Radar Module Overview

Слика 1: Готовоview of the JMT HLK-LD2450 radar module, illustrating its compact design for human movement trajectory tracking.

2. Кључне карактеристике

  • Trajectory Tracking: Real-time tracking of moving targets, outputting distance, angle, and speed data.
  • Application Scenes: Optimized for indoor environments including homes, offices, and hotels for human presence and movement detection.
  • Угао детекције: Azimuth ± 60° / Tilt ± 35°.
  • Тачност угла: 2° до 20°.
  • Удаљеност детекције: Maximum sensing distance of 8 meters.
  • Прецизност мерења удаљености: 0.15 метара.
  • Излаз података: Serial ASCII format.
  • Модулациони режим: FMCW (Frequency Modulated Continuous Wave).
  • учесталост: 24G-24.25GHz (ISM band).
  • Sweep Bandwidth: 250MHz (CE/FCC compliant).
  • Брзина преноса серијског порта: 256000, with 1 stop bit and no parity bit.
  • Пакет: Default 1.5mm x 4Pin Female connector.

3. Техничке спецификације

ПараметарВалуе
Фреквенција24Г-24.25ГХз
Свееп Бандвидтх250MHz (CE/FCC compliant)
Модулатион МодеФМЦВ
Повер Суппли Волtage5V (Typical)
Ектернал Дименсион15 мм к 40 мм
Detection Angle (Azimuth)± 60°
Detection Angle (Tilt)± 35°
Максимална удаљеност сензора8m
Distance Defense Rate0.75м
Тачност мерења удаљености0.15м
Англе Аццураци2° ~ 20°
Брзина освежавања података10Хз
Температура околине-40°Ц ~ +85°Ц
Формат податакаSerial ASCII output
Брзина преноса серијског порта256000
Конфигурација серијског порта1 stop bit, no parity bit
Тип конектора1.5mm x 4Pin Female (Default)
Тежина артикла9.07 г (0.32 унци)

4. Упутства за подешавање

This section details the physical connection and initial configuration of the HLK-LD2450 module.

4.1. Интерфејс модула

The module features a 4-pin interface for power and serial communication. Refer to the diagram below for pin assignments.

HLK-LD2450 Product Diagram with Pinout

Слика 2: HLK-LD2450 module dimensions and interface pinout. The module measures 15mm x 40mm.

  • 1: VCC - 5V Power Input
  • 2: ГНД - Power Ground
  • 3: TX - Serial Transmission (Output from module)
  • 4: РКС - Serial Port Reception (Input to module)

Обезбедите исправан поларитет и јачину звукаtage when connecting the power supply. Incorrect connections may damage the module.

4.2. Физичка инсталација

The module is suitable for wall-mounted installation in indoor environments. Consider the detection angle specifications (Azimuth ± 60° / Tilt ± 35°) to optimize coverage for the desired tracking area.

HLK-LD2450 Module with Pin Headers

Слика 3: The HLK-LD2450 module showing the pin headers for connection, designed for motion positioning and tracking.

5. Упутство за употребу

The HLK-LD2450 module communicates via a serial port, outputting target information in ASCII format.

5.1. Serial Communication Parameters

  • Број бауда: 256000
  • Стоп битови: 1
  • Бит парности: Ниједан

5.2. Using the Configuration Tool

To interact with the module and retrieve data, use the dedicated Configuration Tool (software provided separately by the manufacturer, if applicable). Follow these steps:

  1. Connect the HLK-LD2450 module to your computer via a serial interface (e.g., USB-to-serial converter).
  2. Open the Configuration Tool software.
  3. In the Configuration Tool, select the correct serial port number (COM port) corresponding to your connected module.
  4. Ensure the serial port information (baud rate, stop bits, parity) matches the module's specifications (256000, 1 stop bit, no parity).
  5. Click the "Detect Device" button within the Configuration Tool.
  6. Once the module is detected, click "Start" to begin receiving moving target information from the detection area.

Важна напомена: The serial port tool and the host tool cannot be used simultaneously. Ensure only one application is accessing the serial port at any given time.

6. Одржавање

The JMT HLK-LD2450 module is designed for reliable operation with minimal maintenance. Adhere to the following guidelines:

  • Услови животне средине: Operate the module within the specified ambient temperature range of -40°C to +85°C. Avoid exposure to extreme humidity, dust, or corrosive environments.
  • Чишћење: Ако је потребно, нежно очистите површину модула меком, сувом крпом. Не користите течна средства за чишћење или раствараче.
  • Физичко руковање: Handle the module with care to prevent physical damage to the PCB or components. Avoid bending or applying excessive force.
  • Напајање: Ensure a stable 5V power supply is used. Fluctuations or incorrect voltage can affect performance or damage the module.

КСНУМКС. Решавање проблема

This section provides solutions to common issues you might encounter with the HLK-LD2450 module.

7.1. No Data Output / Connection Issues

  • Проверите снагу: Verify that the module is receiving a stable 5V power supply and that the VCC and GND connections are correct.
  • Serial Port Selection: Ensure the correct COM port is selected in your Configuration Tool or serial terminal software.
  • Serial Port Parameters: Confirm that the baud rate is set to 256000, with 1 stop bit and no parity bit.
  • Кабловске везе: Inspect all serial communication cables for proper connection and integrity. Ensure TX and RX lines are correctly cross-connected if using a direct serial connection (TX of module to RX of host, RX of module to TX of host).
  • Сукоб софтвера: Remember that the serial port tool and the host tool cannot be used at the same time. Close any other applications that might be accessing the serial port.
  • Проблеми са возачем: Ensure that the drivers for your USB-to-serial converter (if used) are correctly installed and up-to-date.

7.2. Inaccurate or Intermittent Tracking

  • Препреке: Ensure there are no significant physical obstructions (e.g., thick walls, large metal objects) between the module and the target area that could interfere with radar signals. While the module can detect through thin materials, dense objects will block signals.
  • Положај монтаже: Adjust the module's mounting position and angle to ensure optimal coverage of the desired detection area, considering the specified Azimuth and Tilt angles.
  • Сметње у животној средини: While 24GHz is robust, strong electromagnetic interference in the immediate vicinity could potentially affect performance.

8. Информације о гаранцији

Specific warranty details for the JMT HLK-LD2450 module are not provided in the available product information. Please refer to the seller or manufacturer's official webсајт за услове гаранције.

9. Корисничка подршка

For technical assistance, further documentation, or inquiries regarding the JMT HLK-LD2450 module, please contact your point of purchase or visit the official JMT website. Support contact information is not available in the provided product data.

© 2024 JMT. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.