1. Увод
This manual provides detailed instructions for the assembly, installation, and operation of your DIGITUS SOHO Pro 7U Network Cabinet, Model DN-49203. Please read these instructions carefully before beginning assembly to ensure safe and correct installation.
Безбедносне информације
- Пре склапања уверите се да су све компоненте присутне и неоштећене.
- Always use appropriate tools and follow safety guidelines during installation.
- The cabinet is designed for a maximum load capacity of 60 kg (132.3 lbs). Do not exceed this limit.
- Wall mounting requires suitable fasteners for your wall type (not included). Consult a professional if unsure.
- Држите децу и кућне љубимце даље од места за окупљање.
Слика 1: Предња страна view of the assembled DIGITUS SOHO Pro 7U Network Cabinet.
2. Карактеристике производа
The DIGITUS SOHO Pro 7U Network Cabinet offers a robust and versatile solution for housing network and server equipment.
- Универзална компатибилност: 19-inch rack with 7U height for standard network and server installations.
- Адјустабле Проfile шине: 483mm (19") profile rails on the front for flexible mounting of accessories, adjustable in depth.
- Ефикасно управљање кабловима: Integrated cable entries with removable plastic caps at the top and bottom.
- Безбедан приступ: Lockable front door made of safety glass, providing protection against unauthorized access.
- Passive Ventilation: Ventilation slots on the front and pre-drilled brackets for optional ceiling-mounted fan units.
- Робусна конструкција: Made from durable sheet steel, supporting a maximum load of 60 kg.
- Flexible Door Hinge: Door hinge can be changed to open from either side, with a 200° opening angle.
- ИП20 Оцена: Protected against solid foreign objects larger than 12.5 mm.
Слика 2: Предња страна view of the cabinet with the glass door closed.
3. Упутство за монтажу
The DIGITUS SOHO Pro Network Cabinet is delivered unassembled for optimized transport. Follow these steps for assembly.
3.1. Распакивање и почетно подешавање
- Step 1: Unpack the Cabinet Components. Carefully remove all parts of the 19-inch SOHO cabinet from its packaging. Ensure all components are present and undamaged.
- Step 2: Open Side Panels. Open the hinged side panels of the cabinet body.
Figure 3: Visual guide for assembly steps 1-4.
3.2. Attaching Base and Door
- Корак 3: Причврстите доњи панел. Slide the bottom plate onto the cabinet body, ensuring the recesses of the bottom plate align and insert into the gaps of the body. Secure the bottom panel to the body using the provided screws. For 9U/12U cabinets, ensure horizontal screws are mounted first, followed by vertical screws. Mount the plastic door stopper on the lock side of the glass door.
- Step 4: Install Glass Door (Bottom Hinge). Lay the cabinet body down with the bottom panel facing the backside. Insert the top hinge pin of the glass door into the hinge hole of the top panel.
Figure 4: Detail of the door hinge installation.
3.3. Finalizing Assembly
- Step 5: Attach Top Panel. Slide the top panel onto the body, aligning the recesses. Insert the top hinge pin of the glass door into the hinge hole of the top panel. Ensure the top panel recesses are inserted into the panel gap of the body. Assemble the bottom panel to the body using 4 screws.
- Step 6: Position Cabinet. Place the cabinet upright on the floor. Bend the recesses of the bottom panel downwards and the recesses of the top panel upwards to secure.
- Step 7: Installation Video. For a visual guide, scan the QR code or visit the provided link to watch the installation video. Your SOHO cabinet is now ready for use.
Figure 5: Visual guide for assembly steps 5-7.
Видео за инсталацију
Watch the official DIGITUS installation video for a step-by-step visual guide to assembling your SOHO Pro Network Cabinet.
3.4. Монтажа на зид
The cabinet is designed for wall mounting. Ensure the wall can support the cabinet's weight plus the weight of installed equipment (up to 60 kg total).
- Identify suitable mounting points on the back of the cabinet.
- Mark the drilling locations on the wall using the cabinet as a template.
- Drill holes and insert appropriate wall anchors (not supplied).
- Причврстите ормарић за зид помоћу вијака.
Слика 6: Задња страна view of the cabinet indicating wall mounting points.
4. Операција
4.1. Installing Equipment
- Open the front glass door using the provided key.
- Adjust the depth of the 19-inch profile rails as needed to accommodate your equipment.
- Mount your 19-inch compatible devices (e.g., switches, patch panels, servers) to the profile rails using appropriate rack screws (not included).
Слика 7: Унутрашњост view with the glass door open, highlighting adjustable profile шине.
4.2. Менаџмент каблова
- Utilize the cable entry points located at the top and bottom of the cabinet for routing network cables.
- Remove the plastic caps from the cable entries as needed.
- Ensure cables are neatly organized and secured to prevent strain or interference.
Figure 8: Detail of the cable entry at the base.
4.3. Вентилација
- The cabinet features passive ventilation through slots on the front.
- For enhanced cooling, optional fan units can be installed in the pre-drilled brackets on the ceiling of the cabinet.
Слика 9: Врх view showing fan cutouts and cable entry.
5. Одржавање
- Чишћење: Обришите спољашње површине меком, дamp крпу. Избегавајте абразивна средства за чишћење или раствараче.
- инспекција: Periodically check all screws and fasteners to ensure they are tight. Inspect the door hinges and lock for proper function.
- вентилација: Ensure ventilation slots are not obstructed to maintain proper airflow.
КСНУМКС. Решавање проблема
Most issues with the network cabinet are related to assembly or installation. Refer to the assembly instructions if you encounter any difficulties.
- Cabinet is wobbly after assembly: Recheck all screw connections to ensure they are tightened securely. Ensure the cabinet is placed on a level surface or properly mounted to the wall.
- Врата се не затварају правилно: Verify that the door hinges are correctly installed and aligned. Check for any obstructions. The door hinge can be adjusted or reversed if needed.
- Difficulty inserting equipment: Ensure the 19-inch profile rails are correctly positioned and adjusted to the required depth.
7. Спецификације
| Атрибут | Валуе |
|---|---|
| Бранд | Дигитус |
| Број модела | ДН-КСНУМКС |
| Величина | 7U |
| Боја | Црно/Бело |
| Димензије производа (Д x Ш x В) | 400 мм Д x 540 мм Ш x 370 мм В |
| Useful Depth | 327мм |
| Материјал | Метал |
| Тежина артикла | 9.4 килограма (20.7 лбс) |
| Тежина Капацитет | 60 кг (132.3 лбс) |
| Тип монтаже | Rack Mount, Wall Mount |
| Материјал кућишта | Метал |
| Обавезна монтажа | Да |
8. Гаранција и подршка
For warranty information and technical support, please refer to the documentation included with your purchase or visit the official Digitus webсајт. Сачувајте доказ о куповини за потребе гаранције.
If you have further questions or require assistance, please contact Digitus customer service.