LumeGen LG-2T8-8-AB-5CCT

LumeGen 2-Pack 2ft LED Universal Tube Instruction Manual

Model: LG-2T8-8-AB-5CCT

1. Важне информације о безбедности

Please read all instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or other hazards. Keep this manual for future reference.

  • УПОЗОРЕЊЕ: Опасност од струјног удара. Искључите напајање на прекидачу или кутији са осигурачима пре инсталације или сервисирања.
  • This product is designed for use in dry or damp локацијама. Не користити тамо где је директно изложено води.
  • Do not attempt to modify the tube or its components.
  • Уверите се да је уређај правилно уземљен.
  • For Type B (ballast bypass) installation, wiring should be performed by a qualified electrician to ensure safety and compliance with local electrical codes.
  • Do not look directly into the operating LED tube.

2. Производ је готовview

The LumeGen 2ft LED Universal Tube is an energy-efficient lighting solution designed for versatile applications. It features a color temperature selector, allowing you to choose from five different white light options. Its shatterproof design ensures durability and safety.

Two LumeGen 2ft LED Universal Tubes showing the color temperature selector switch.

Image: Two LumeGen 2ft LED Universal Tubes, highlighting the adjustable color temperature switch on each tube.

Кључне карактеристике:

  • Разноврсна компатибилност: Supports both Type A (ballast compatible) and Type B (ballast bypass/direct wire) installations.
  • Прилагодљива температура боје: Easily switch between 3000K (Warm White), 3500K (Neutral White), 4000K (Cool White), 5000K (Daylight), and 6500K (Bright Daylight).
  • Shatterproof and Durable Design: Constructed with a PET-coated glass body and frosted lens for enhanced safety and longevity. UL Listed for quality assurance.
  • Енергетски ефикасан: Consumes only 8W while delivering 1100 lumens, offering significant energy savings compared to traditional fluorescent tubes.
  • Дуг животни век: Rated for 50,000 hours of operation, reducing the need for frequent replacements.

3. Спецификације

СпецификацијаВалуе
БрандЛумеГен
Број моделаLG-2T8-8-AB-5CCT
Лигхт ТипеЛЕД
Ватtage8 Ваттс
Осветљеност1100 лумена
Ефикасност137.5 лумена по вату
Величина облика сијалицеT8
Булб БасеГ13
Температура боје3000K/3500K/4000K/5000K/6500K (Selectable)
Волtage100-120 волти
Фреквенција60 Хертз
Просечан живот50,000 сата
МатеријалPlastic (PET-coated glass)
Финисх ТипеСмрзнуто
Унутрашња/спољна употребаИндоор
Димензије (приближно)49.37 inches (Length)
Diagram showing the dimensions of the LumeGen LED tube and its color temperature selector.

Image: Product dimensions and color temperature selector detail.

4. Инсталација (Подешавање)

The LumeGen Universal Tube supports both Type A (ballast compatible) and Type B (ballast bypass/direct wire) installations. Always ensure power is OFF before beginning installation.

Graphic indicating the LED tube supports both Type A and Type B installations.

Image: The LED tube is compatible with both Type A (ballast compatible) and Type B (ballast bypass) systems.

4.1. Type A (Ballast Compatible) Installation

This method uses your existing electronic ballast. Ensure your ballast is compatible with LED T8 tubes. Refer to your ballast's specifications for compatibility.

  1. Искључите напајање: Locate the circuit breaker controlling the fixture and turn off the power. Verify power is off using a voltagе тестер.
  2. Уклоните старе цеви: Carefully remove the existing fluorescent tubes from the fixture.
  3. Install LED Tubes: Insert the LumeGen LED tubes into the fixture's sockets. Ensure they are securely seated.
  4. Врати снагу: Поново укључите напајање на прекидачу.

4.2. Type B (Ballast Bypass / Direct Wire) Installation

This method bypasses the existing ballast and wires the fixture directly to the main power supply. This installation should only be performed by a qualified electrician.

  1. Искључите напајање: Locate the circuit breaker controlling the fixture and turn off the power. Verify power is off using a voltagе тестер.
  2. Remove Old Tubes and Ballast: Carefully remove the existing fluorescent tubes. Then, open the fixture and disconnect the wiring from the ballast. Remove the ballast from the fixture.
  3. Rewire Fixture: Wire the fixture's lamp holders directly to the main power supply (100-120V AC, 60Hz). The LumeGen LED tube is single-ended powered, meaning power is supplied to one end of the tube. Connect the live (L) and neutral (N) wires to the pins on one end of the tube's socket. Consult the wiring diagram provided with the product packaging for specific instructions.
  4. Install LED Tubes: Insert the LumeGen LED tubes into the rewired fixture's sockets. Ensure they are securely seated.
  5. Врати снагу: Поново укључите напајање на прекидачу.
Collage of images showing a person installing an LED tube into a light fixture.

Image: Visual representation of the LED tube installation process.

5. Операција

The LumeGen LED Universal Tube features a convenient switch to select your desired color temperature.

  1. Ensure Power is On: After installation, turn on the power to the fixture.
  2. Locate the CCT Switch: On one end of the LED tube, you will find a small slider switch labeled with color temperature options (3000K, 3500K, 4000K, 5000K, 6500K).
  3. Изаберите температуру боје: Gently slide the switch to the desired Kelvin (K) setting. The light output will change immediately to reflect your selection.
  4. Прилагодите по потреби: You can change the color temperature at any time while the tube is powered on.

6. Одржавање

The LumeGen LED Universal Tube requires minimal maintenance.

  • Чишћење: Пре чишћења проверите да ли је напајање искључено. Користите меку, суву или благо длаку.amp cloth to wipe the surface of the tube. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the tube's finish or coating.
  • инспекција: Periodically inspect the tubes and fixture for any signs of damage or loose connections. If any issues are found, disconnect power and address them promptly.
  • Складиштење: If storing the tubes, keep them in their original packaging in a cool, dry place away from direct sunlight and extreme temperatures.

КСНУМКС. Решавање проблема

If you encounter issues with your LumeGen LED Universal Tube, refer to the following common problems and solutions:

ПроблемМогући узрокРешење
Tube does not light up.Нема струје за уређај.
Improper installation (loose connection).
Incompatible ballast (for Type A).
Faulty tube.
Проверите осигурач и зидни прекидач.
Ensure tubes are securely seated in sockets. For Type B, verify wiring.
If Type A, confirm ballast compatibility or consider Type B installation.
Test with another known working tube if available.
Tube flickers.Incompatible ballast (for Type A).
Лабава веза.
Волtagе флуктуације.
If Type A, ensure ballast is compatible. Some older ballasts may cause flickering. Consider Type B installation.
Проверите везе.
Консултујте електричара ако је волуменtagСумња се на проблеме.
Нетачна температура боје.CCT прекидач је погрешно подешен.Adjust the CCT selector switch on the tube to the desired setting.
Смањена осветљеност.Dust or dirt on tube surface.
End of tube lifespan.
Clean the tube surface with a soft, dry cloth.
If tube is near end of its rated lifespan, replacement may be necessary.

8. Гаранција и подршка

LumeGen products are manufactured to high-quality standards. This product comes with a limited warranty against defects in materials and workmanship. For specific warranty details, please refer to the product packaging or contact LumeGen customer support.

If you require technical assistance, have questions about installation, or need to report a defect, please contact LumeGen customer support through the retailer where the product was purchased or visit the official LumeGen webсајт за контакт информације.

LumeGen Store: Visit the LumeGen Store on Amazon

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.