VEVOR DC-0506 Laboratory Chiller Circulator User Manual

Модел: ДЦ-0506

1. Увод

This manual provides essential instructions for the safe and efficient operation of your VEVOR DC-0506 Laboratory Chiller Circulator. This unit is designed for precise temperature control in laboratory environments, offering both heating and cooling capabilities within a range of -5℃ to 100℃. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper use and to prevent damage to the equipment or injury to personnel.

2. Безбедносне информације

Adherence to the following safety guidelines is crucial for safe operation:

  • Уверите се да је уређај повезан са уземљеном утичницом са исправним напономtage.
  • Do not operate the chiller with damaged power cords or plugs.
  • Always use appropriate liquid media as specified (e.g., ethanol for low temperatures). Do not use flammable or corrosive liquids without proper safety precautions and compatibility checks.
  • Avoid direct contact with hot or cold surfaces during operation. Use protective gloves if necessary.
  • Do not block ventilation openings on the unit. Ensure adequate clearance for airflow.
  • Искључите напајање пре него што извршите било какво одржавање или чишћење.
  • Keep the unit away from water splashes or excessive humidity.
  • In case of malfunction, switch off the unit immediately and consult the troubleshooting section or contact support.

3. Производ је готовview

The VEVOR DC-0506 Laboratory Chiller Circulator is a robust unit designed for precise temperature management in various scientific applications. It features a fully enclosed compressor for efficient and quiet operation, a high-definition LCD for accurate control, and a durable 304 stainless steel construction.

Кључне компоненте

  • Контролна табла: Features an LCD display for temperature monitoring and control buttons.
  • Резервоар за воду: 6L capacity, made of 304 stainless steel for corrosion resistance.
  • Циркулациона пумпа: Ensures consistent liquid flow for stable temperature.
  • компресор: Fully enclosed, providing fast and stable cooling.
  • Одводни вентил: Located on the side for easy liquid drainage.
  • Internal/External Circulation Ports: Allows for flexible integration with external equipment.
Diagram of VEVOR Laboratory Chiller Circulator with labeled components
Слика 3.1: Завршеноview of the VEVOR DC-0506 Chiller Circulator with key components labeled, including the stainless steel tank, control panel, handles, and drain valve.
Унутрашње view of the VEVOR Laboratory Chiller Circulator showing the fully enclosed compressor
Figure 3.2: Illustration highlighting the fully enclosed compressor, responsible for efficient and quiet cooling, ensuring long-lasting temperature stability.

4. Подешавање

Follow these steps to set up your chiller circulator:

  1. Распакивање: Пажљиво извадите уређај из амбалаже. Проверите да ли је дошло до оштећења приликом транспорта. Сачувајте амбалажу за будући транспорт или складиштење.
  2. Пласман: Place the chiller on a stable, level surface in a well-ventilated area. Ensure there is sufficient space around the unit for proper airflow (at least 20 cm on all sides).
  3. Connecting External Devices (Optional): If using external circulation, connect the inlet and outlet ports of the chiller to your external equipment using appropriate tubing. Ensure all connections are secure to prevent leaks.
Diagram showing internal and external circulation modes for the VEVOR Laboratory Chiller Circulator
Figure 4.1: The chiller supports both internal circulation for direct bath applications and external circulation for integration with other laboratory equipment.
  1. Filling with Liquid Medium: Open the cover of the water tank. Fill the tank with the recommended liquid medium (e.g., ethanol for temperatures below 8℃, or distilled water for higher temperatures). Ensure the liquid level is between the minimum and maximum fill lines.

Video 4.1: This video demonstrates the process of connecting the chiller to an external device and filling the tank with the appropriate liquid medium.

  1. Прикључак за напајање: Connect the power cord to the unit and then to a grounded electrical outlet.

5. Упутство за употребу

The VEVOR DC-0506 features an intuitive LCD control panel for easy operation.

  1. Укључивање/искључивање: Притисните дугме за напајање на контролној табли да бисте укључили или искључили уређај.
  2. ЛЦД екран: The high-definition LCD displays the current temperature and set temperature with an accuracy of 0.01℃.
Close-up of the LCD smart temperature control panel on the VEVOR Laboratory Chiller Circulator
Figure 5.1: The LCD control panel provides clear digital display and precise temperature adjustment with 0.01℃ resolution.
  1. Подешавање температуре: Use the 'SET' button and arrow keys on the control panel to adjust the desired temperature. The unit will automatically work to reach and maintain this set point.
  2. Режими грејања и хлађења: The chiller automatically switches between heating and cooling to maintain the set temperature within the range of -5℃ to 100℃.
Graphic illustrating the heating and cooling capabilities of the VEVOR Laboratory Chiller Circulator
Figure 5.2: The chiller offers both heating (up to 100℃) and cooling (down to -5℃) functions, suitable for diverse experimental needs.
  1. Circulation Modes: The unit supports both internal and external circulation. Select the appropriate mode based on your application.
  2. Сигурносне карактеристике: The chiller includes built-in overheat and overcurrent protection, along with an overheat alarm, to ensure safe operation.

6. Одржавање

Regular maintenance ensures the longevity and optimal performance of your chiller circulator.

  • Draining Liquid: Periodically drain the liquid medium from the tank using the drain valve. This is especially important before long periods of inactivity or when changing the liquid medium.
Сиде view of the VEVOR Laboratory Chiller Circulator showing the draining valve
Figure 6.1: The draining valve on the side of the unit allows for convenient removal of the liquid medium after use or for maintenance.
  • Чишћење резервоара: After draining, clean the interior of the 304 stainless steel tank with a mild detergent and rinse thoroughly with distilled water. Ensure no residue remains.
Врх view of the VEVOR Laboratory Chiller Circulator with the tank cover open
Figure 6.2: The open tank allows for easy access for cleaning and refilling of the liquid medium.
  • Спољно чишћење: Обришите спољашње површине меком, дamp тканина. Избегавајте абразивна средства за чишћење.
  • вентилација: Regularly check that the ventilation grilles are free from dust and debris to ensure efficient heat dissipation.
  • Замена течности: Replace the liquid medium regularly according to your experimental needs and the manufacturer's recommendations for the specific fluid used.

КСНУМКС. Решавање проблема

If you encounter issues with your chiller, refer to the following common problems and solutions:

ПроблемМогући узрокРешење
Jedinica se ne uključujeNo power supply; Power cord loose; Power switch offCheck power connection; Ensure power switch is on; Test outlet
Temperature not stable/reachedInsufficient liquid medium; Blocked circulation; Incorrect set temperature; Ambient temperature too high/lowCheck liquid level and refill; Inspect tubing for kinks; Verify set temperature; Ensure proper ventilation
Overheat alarm activatesInsufficient liquid; Blocked ventilation; Internal faultCheck liquid level; Clear ventilation openings; Contact support if problem persists
Цурење течностиLoose connections; Damaged tubing/tankTighten all connections; Replace damaged tubing; Contact support for tank issues

Ако проблем и даље постоји након покушаја ових решења, обратите се корисничкој подршци компаније VEVOR.

8. Спецификације

Detailed technical specifications for the VEVOR DC-0506 Laboratory Chiller Circulator:

ФеатуреСпецификација
Број модела ставкеДЦ-0506
Називна снага1000W (САД) / 800W (ЕУ, Аустралија)
Min Constant Temperature23°Ф / -5°Ц
Max Constant Temperature212°Ф / 100°Ц
Temperature Adjustment AccuracyНочьу 0.01°Ц
Капацитет резервоара за воду≥5Л
Water Opening Tank Size7.1 к 6.3 к 5.9 ин / 18 к 16 к 15 цм
Countertop Water Tank Material304 нерђајући челик
Net Weight (Including all Accessories)54.5 lbs / 24.7 KG
Димензије производа29.13 к 18.11 к 16.14 инча
Diagram showing dimensions and key specifications of the VEVOR Laboratory Chiller Circulator
Figure 8.1: Visual representation of the chiller's dimensions and a summary of its technical specifications.

9. Шта је у кутији

Након распакивања, требало би да пронађете следеће ставке:

  • 1 x Laboratory Chiller Circulator (Model DC-0506)
Image of the VEVOR Laboratory Chiller Circulator and included accessories
Figure 9.1: The main unit and standard accessories included with the VEVOR DC-0506 Laboratory Chiller Circulator.

10. Гаранција и подршка

VEVOR products are designed for reliability and performance. For warranty information, please refer to the documentation provided with your purchase or visit the official VEVOR website. If you require technical assistance, troubleshooting guidance, or have questions regarding your product, please contact VEVOR customer support. Have your model number (DC-0506) and purchase details ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.