Alarm.com ADC-AC-ET10

Alarm.com ADC-AC-ET25 Keypad Reader User Manual

Model: ADC-AC-ET10

1. Увод

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Alarm.com ADC-AC-ET25 Keypad Reader. Designed for Smarter Access Control, this reader integrates multiple credential technologies to enhance security and flexibility for businesses.

Кључне карактеристике:

  • Multiple Technologies: Supports Proximity, NFC, and Bluetooth Low Energy (BLE) credentials in a single device.
  • Mobile Credentials: Enables the use of smartphones to unlock doors, reducing reliance on physical badges.
  • OSDP Auto-Detect & Secure Channel: Ensures secure communication and automatic detection of OSDP devices.
  • Могућност надоградње фирмвера: Supports remote firmware updates for continuous improvement and security enhancements.
  • Credential Support: Compatible with I-FARE DESFire EV1 & EV2, and LEAF credentials for secure, open interoperability. Also supports FSK and ASK legacy proximity credentials for seamless transitions.
  • Tampер детекција: Features accelerometer-based tamper detection for enhanced security.
  • Visual & Audible Indicators: Equipped with a tri-state LED light bar (red, green, amber) and an audible beeper for status feedback.
  • Разноврсна инсталација: Погодно за унутрашње и спољашње окружење.

2. Безбедносне информације

Пажљиво прочитајте сва безбедносна упутства пре инсталирања или рада уређаја. Непоштовање ових упутстава може довести до оштећења уређаја, имовине или телесних повреда.

  • Ensure all electrical connections are made by a qualified professional and comply with local electrical codes.
  • Искључите напајање пре него што извршите било какву инсталацију или одржавање.
  • Do not expose the device to extreme temperatures, humidity, or direct water immersion beyond its specified environmental ratings.
  • Avoid placing the device near strong electromagnetic fields, which may interfere with its operation.
  • Не покушавајте сами да растављате или поправљате уређај. Све сервисирање препустите квалификованом особљу.

3. Садржај пакета

Пре него што наставите са инсталацијом, проверите да ли су све ставке присутне у пакету:

  • Alarm.com ADC-AC-ET25 Keypad Reader
  • Монтажни прибор (вијци, анкери)
  • Шаблон за инсталацију (ако је применљиво)
  • Кратки водич (за више детаља погледајте овај приручник)

4. Производ је готовview

The ADC-AC-ET25 Keypad Reader is a robust access control device featuring a numeric keypad and multi-technology credential reading capabilities. Its design allows for seamless integration into various security systems.

Alarm.com ADC-AC-ET25 Keypad Reader with numeric keypad and green LED indicator

Слика 4.1: Фронт view of the Alarm.com ADC-AC-ET25 Keypad Reader. The device is black with a prominent numeric keypad (0-9, *, #) in the center. A green LED light bar is visible at the top, indicating operational status. The "ALARM.COM" logo is located at the bottom.

Компоненте:

  • Тастатура: Numeric keys (0-9), asterisk (*), and hash (#) for PIN entry.
  • ЛЕД светлосна трака: Tri-state (red, green, amber) indicator for status feedback.
  • Credential Reader Area: Integrated area for Proximity, NFC, and BLE mobile credential scanning.
  • Tamper Sensor: Accelerometer-based sensor to detect unauthorized removal or tampеринг.

5. Подешавање и инсталација

The ADC-AC-ET25 Keypad Reader is designed for flexible installation in both indoor and outdoor environments. Proper installation is crucial for optimal performance and security.

5.1. Контролна листа пре инсталације:

  • Verify the mounting surface is suitable and secure.
  • Ensure proper wiring and power supply are available at the installation site.
  • Confirm compatibility with your existing access control panel (supports OSDP).

5.2. Монтажа:

  1. Choose a suitable mounting location, considering accessibility and environmental factors.
  2. Use the provided mounting template to mark drilling points on the wall.
  3. Избушите рупе и уметните анкере ако је потребно.
  4. Secure the reader's backplate to the wall using the provided screws.

5.3. Ожичење:

Connect the reader to your access control panel according to the wiring diagram provided with your panel and the reader's specific wiring instructions (typically found on the back of the reader or in a dedicated wiring guide). The reader supports OSDP Auto-Detect and Secure Channel for enhanced communication security.

5.4. Појачајте:

Once wiring is complete and verified, apply power to the access control system. The reader's LED light bar will indicate its power-up sequence and operational status.

6. Упутство за употребу

The ADC-AC-ET25 Keypad Reader offers multiple methods for access, providing flexibility for users.

6.1. Using Credentials:

  • Proximity/NFC Cards/Fobs: Present your compatible card or fob within close proximity to the reader's front surface. The reader will emit an audible beep and the LED will change color (typically green) upon successful read.
  • Bluetooth Low Energy (BLE) Mobile Credentials: Ensure your smartphone has the Alarm.com mobile access app installed and BLE is enabled. Approach the reader with your phone. The app will communicate with the reader to grant access.

6.2. Using the Keypad (PIN Entry):

  1. Enter your assigned Personal Identification Number (PIN) using the numeric keypad.
  2. Press the hash (#) key to confirm your entry.
  3. Upon successful PIN entry, the reader will provide an audible and visual confirmation (e.g., green LED).

6.3. LED Indicator Meanings:

  • зелено: Access granted, successful credential read, or system ready.
  • црвено: Access denied, error, or system fault.
  • Амбер: Standby, processing, or specific system status (refer to your access control system documentation for detailed amber indications).

7. Одржавање

Regular maintenance ensures the longevity and optimal performance of your ADC-AC-ET25 Keypad Reader.

  • Чишћење: Користите меку, дamp cloth to clean the exterior of the reader. Do not use abrasive cleaners, solvents, or excessive moisture.
  • Ажурирања фирмвера: The reader supports remote firmware upgradability. Your access control system administrator will manage these updates to ensure the device has the latest features and security patches.
  • инспекција: Periodically inspect the reader for any signs of physical damage or loose connections.

КСНУМКС. Решавање проблема

This section addresses common issues you might encounter with the ADC-AC-ET25 Keypad Reader.

  • Reader is unresponsive (no lights, no sound):
    • Check power supply to the reader and access control panel.
    • Проверите да ли су ожичење безбедно и исправно повезано.
  • Credential not granting access (red LED):
    • Ensure the credential is valid and active in the access control system.
    • Confirm the credential type is supported by the reader (Proximity, NFC, BLE).
    • Try presenting the credential again, ensuring proper alignment.
  • Keypad entry not working:
    • Verify the PIN is correct and active.
    • Ensure the hash (#) key is pressed after entering the PIN.
  • Tamper alarm triggered:
    • Check if the reader has been dislodged or moved from its mounting.
    • Securely re-mount the reader if necessary.

For persistent issues, contact your system administrator or technical support.

9. Спецификације

АтрибутДетаљ
Број моделаADC-AC-ET10
ПроизвођачАларм.цом
Димензије (Д к Ш к В)8.38 к 1.78 к 12.95 цм
Подржане технологијеProximity, NFC, Bluetooth Low Energy (BLE)
Подршка за акредитивеI-FARE DESFire EV1 & EV2, LEAF, FSK, ASK
Цоммуницатион ПротоцолOSDP (Open Supervised Device Protocol) with Secure Channel
ИндикаториTri-state LED (Red, Green, Amber), Audible Beeper
Tampер ДетецтионAccelerometer-based
Инсталационо окружењеУнутрашњи и отворени
Земља пореклаКанада

10. Информације о гаранцији

Specific warranty terms and conditions for the Alarm.com ADC-AC-ET25 Keypad Reader are typically provided at the point of purchase or by the manufacturer. Please refer to the documentation included with your purchase or contact your seller/installer for detailed warranty information. Keep your proof of purchase for warranty claims.

11. Корисничка подршка

For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact your authorized Alarm.com dealer or the seller from whom you purchased the product. Provide your product model number (ADC-AC-ET10) and a detailed description of the issue when seeking support.

Произвођач: Аларм.цом