EARU EARU1036

EARU 32A Circuit Breaker Instruction Manual

Model: EARU1036

1. Производ је готовview

The EARU 32A Circuit Breaker (Model EARU1036) is an Advanced Protection Suite (APS) designed to safeguard electrical circuits, appliances, and personnel. It integrates multiple protection functions into a single device, ensuring comprehensive safety and reliability for various electrical installations.

Кључне карактеристике:

2. Безбедносне информације

Please read all safety instructions carefully before installing, operating, or maintaining this device. Failure to follow these instructions may result in electrical shock, fire, serious injury, or death.

3. Product Components and Wiring Diagram

Familiarize yourself with the main components and the correct wiring configuration of the EARU 32A Circuit Breaker.

Детаљно view of EARU 32A Circuit Breaker components and wiring diagram

Слика 1: Детаљно view of the EARU 32A Circuit Breaker, highlighting its terminals, operating handle, test button, wiring diagram, surge protection indicator, reset button, fastening screws, and flame retardant housing. The diagram shows connections for Line (L), Neutral (N), and Protective Earth (PE). It emphasizes that the circuit must be wired and grounded correctly to ensure proper operation and protection.

Product Dimensions and Parameters

Dimensions and key parameters of EARU 32A Circuit Breaker

Слика 2: This image displays the physical dimensions of the EARU 32A Circuit Breaker (94mm height, 71mm width, 45mm depth) and lists key product parameters such as Product Series (EADZ47L-32SVP), Rated Voltage (AC230V), Mechanical Lifespan (20000 cycles), Compliance Standard (IEC61009-1), Rated Residual Operating Current (30mA), Poles (2P+PE/4Pole), Product Certification (CE), and Breaking Capacity (6000A). It also highlights advanced features like overload, short circuit, lightning, leakage, over-undervoltage protection, smart reset, and real-time monitoring.

4. Инсталација

The EARU 32A Circuit Breaker is designed for DIN-rail mounting. Ensure the installation environment is dry, well-ventilated, and free from corrosive substances.

Кораци инсталације:

  1. Монтажа: Securely attach the circuit breaker to a standard DIN rail in your electrical panel.
  2. Ожичење: Погледајте Слика 1 for the wiring diagram. Connect the incoming Line (L) and Neutral (N) wires to the top terminals and the outgoing load wires to the bottom terminals. Ensure the Protective Earth (PE) is correctly connected.
  3. Затезање терминала: Use appropriate tools to tighten all fastening screws on the terminals to ensure secure electrical contact and prevent loose connections, which can cause overheating or arcing.
  4. Верификација: Double-check all wiring connections for correctness and tightness before restoring power.
EARU Circuit Breaker installed in an electrical panel

Слика 3: An EARU Circuit Breaker installed on a DIN rail within an electrical panel, demonstrating a typical installation scenario with connected wiring.

5. Упутство за употребу

Basic Operation and Leakage Protection Test

Follow these steps for normal operation and to periodically test the leakage protection function of your circuit breaker.

Instructions for powering on and testing leakage protection

Слика 4: This image illustrates the basic operating instructions. 1. корак: To power on, pull up the operating handle (red switch) and ensure the 'R' button is protruding, indicating a power-on state. 2. корак: If the handle jumps down automatically and the 'R' button bounces, it signifies a normal power-off state. 3. корак: If the 'R' button is pressed and the handle does not jump down, it indicates a problem. 4. корак: After a successful test or reset, the device returns to a powered-on state.

Detailed instructions for leakage protection device inspection

Слика 5: Detailed instructions for inspecting the leakage protection device. 1. корак: With the operating handle pulled up and the 'R' button not protruding (power-on state), press the 'Test' key to test the leakage protection device. 2. корак: If the handle jumps down automatically and the 'R' button bounces, the device is in a power-off state, indicating the leakage protection device is functioning normally. 3. корак: If the 'Test' switch is pressed and the handle does not jump down, and the 'R' button does not automatically pop up, the device is in an energized state, indicating a problem with the leakage protection device, and it cannot provide protection. A new leakage device needs to be replaced. 4. корак: After a normal inspection (handle automatically jumps down, 'R' button automatically pops up), the device is in a power-off state. Press the 'R' button that just popped up, and then pull up the operating handle to power on the appliance normally.

Parameter Setting (Adjustable Voltage and Current Protector)

The EARU Circuit Breaker allows for adjustment of various protection parameters. The following video demonstrates how to set these parameters.

Видео 1: This video demonstrates how to adjust the protection parameters on an EARU Adjustable Voltage and Current Protector. It shows setting the overvoltage (P-1, range 240-300V), undervoltage (P-2, range 140-200V), overcurrent (P-3, range 1A-40A/63A/80A), reset/start delay (P-4, range 1s-300s), and relay recovery delay (P-5, range 1s-300s) settings. The video also shows the overcurrent recovery delay (P-6, range 1s-300s). This process involves pressing the 'SET' button to enter programming mode and using the up/down arrows to adjust values.

6. Одржавање

Regular maintenance ensures the longevity and reliable operation of your EARU Circuit Breaker.

КСНУМКС. Решавање проблема

If you encounter issues with your EARU Circuit Breaker, refer to the following common troubleshooting steps. For complex problems, contact a qualified electrician.

ПроблемМогући узрокРешење
Уређај се не укључујеIncorrect wiring; No input power; Device faultCheck wiring connections (L, N, PE); Verify main power supply; If wiring and power are correct, device may be faulty and require replacement.
Frequent tripping (Over-Voltagе/Ундер-Волtage)Unstable power supply; Incorrect voltagе подешавањаПроверите долазну линију волtage stability; Adjust over/under voltage settings (refer to Parameter Setting video) if necessary, ensuring they are within safe operating limits for your appliances.
Frequent tripping (Overload/Short Circuit)Excessive load; Short circuit in connected appliance/wiringReduce connected load; Inspect appliances and wiring for short circuits; Adjust overcurrent settings (refer to Parameter Setting video) if appropriate for the load, but do not exceed device rating.
Frequent tripping (Earth Leakage/Electric Shock)Ground fault in connected appliance/wiring; Device faultInspect appliances and wiring for ground faults; Perform leakage protection test (refer to Operating Instructions); If test fails and no external fault is found, device may be faulty.
Leakage protection test fails (handle does not jump down)Leakage protection mechanism faultThe leakage protection device is faulty and cannot provide protection. It must be replaced immediately.

8. Техничке спецификације

Key technical specifications for the EARU 32A Circuit Breaker, Model EARU1036.

СпецификацијаВалуе
БрандЕАРУ
Број моделаEARU1036
Цуррент Ратинг30 Милиamps (Residual Operating Current)
Волtage230 Волтс
Ватtage10000 Ваттс
Димензије производа (Д x Ш x В)20 Д x 12 Ш x 12 В центиметара
Тип прекидачаRCBO, RCCB, ELCB, MCB, Surge Protector
Тип монтажеМонтажа на ДИН шину
Нумбер Оф Полес6 (Implied from 2P+PE/4Pole in image, actual product is 2-pole with earth protection)
Тежина артикла450 г
Извор напајањаАЦ Поверед
Укључене компоненте2 IN ONE (Circuit Breaker)
Земља пореклаИндија
Датум првог доступног10. новембар 2022

9. Гаранција и подршка

The EARU 32A Circuit Breaker comes with a 2-year warranty, backed by GE-authorized service. For warranty claims, technical assistance, or product support, please contact your retailer or the authorized service center.

Произвођач: ЕАРУ

продавац: GE INDIA INC.

Молимо вас да сачувате доказ о куповини ради потврде гаранције.