FeelTech ZT-DQ01

FeelTech ZT-DQ01 Handheld Digital LCR Meter Instruction Manual

Model: ZT-DQ01

Марка: FeelTech

1. Увод

This manual provides detailed instructions for the safe and effective use of the FeelTech ZT-DQ01 Handheld Digital LCR Meter. Please read this manual thoroughly before operation.

The ZT-DQ01 is a high-precision handheld digital bridge LCR meter designed for measuring capacitance, resistance, and inductance. It features a 2.8-inch full-view angle color screen and supports true four-wire measurement.

FeelTech ZT-DQ01 LCR Meter with accessories

Image 1: FeelTech ZT-DQ01 LCR Meter and included accessories.

2. Кључне карактеристике

  • Handheld digital high-precision bridge tester for LCR measurement.
  • Measures resistance, capacitance, and inductance with true four-wire L/C/R/Z value display.
  • Equipped with a 2.8-inch full-view angle color screen.
  • Automatic identification of resistors, capacitors, and inductors.
  • Features an adjustable auto power-off function for energy saving; compact and portable design.
FeelTech ZT-DQ01 LCR Meter highlighting key features

Слика 2: Готовоview of the ZT-DQ01's main features, including true four-wire measurement and L/C/R/Z value display.

3. Подешавање и почетна употреба

3.1 Распакивање

Carefully unpack the ZT-DQ01 LCR Meter and all accessories. Verify that all components listed in the "What's in the Box" section are present:

  • ZT-DQ01 LCR Meter
  • Тест водови
  • УСБ Типе-Ц кабл за пуњење
  • Торбица за ношење

3.2 Пуњење уређаја

The ZT-DQ01 is powered by a 400mA lithium battery. Before first use, fully charge the device using the provided USB Type-C cable and a compatible USB power adapter (not included).

FeelTech ZT-DQ01 LCR Meter display showing battery and Type-C charging port

Image 3: The 2.8-inch color screen and Type-C charging port of the ZT-DQ01.

3.3 Повезивање мерних каблова

Connect the provided test leads to the appropriate input terminals on the LCR meter. Ensure a secure connection for accurate measurements. The meter supports true four-wire measurement for enhanced precision.

FeelTech ZT-DQ01 LCR Meter with test leads connected to a component

Image 4: The ZT-DQ01 LCR Meter connected to a component for testing, demonstrating automatic identification.

4. Упутство за употребу

4.1 Укључивање/искључивање

Притисните и држите дугме за напајање () to turn the device on or off.

4.2 Основна мерења

The ZT-DQ01 features automatic identification of resistors, capacitors, and inductors. Simply connect the component to the test leads, and the meter will automatically detect the component type and display the relevant parameters (L, C, R, Z, X, D, Q, θ, ESR).

4.3 Функцијска дугмад

  • ЧЕСТО: Adjusts the test frequency (100Hz, 120Hz, 1KHz, 10KHz, 100KHz).
  • НИВО: Sets the test level (0.1V, 0.3V, 0.6V).
  • БРЗИНА: Adjusts the measurement speed (Slow, Medium, Fast).
  • X/D/Q/θ/ESR: Cycles through displayed sub-parameters.
  • AUTO/S/P SETUP: Automatic series/parallel mode setup.
  • LCRZ: Selects the main measurement parameter (Inductance, Capacitance, Resistance, Impedance).
  • HOLD/REC: Holds the current measurement or enters record mode.
  • REL TOL%: Relative measurement and tolerance percentage.

4.4 Discharging Capacitors

WARNING: Always discharge capacitors before testing to prevent damage to the meter or injury.

FeelTech ZT-DQ01 LCR Meter showing various function buttons and display

Слика 5: Детаљно view of the ZT-DQ01's control panel and display, illustrating various functions.

5. Одржавање

5.1 Чишћење

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off before cleaning.

5.2 Складиштење

Store the LCR meter in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided carrying pouch for protection.

5.3 Калибрација

The ZT-DQ01 supports bridge calibration for short circuit and open circuit. Refer to the on-screen menu for calibration procedures to maintain measurement accuracy.

КСНУМКС. Решавање проблема

  • Нема напајања: Ensure the battery is charged. Connect the USB Type-C cable to charge.
  • Нетачна очитавања:
    • Check test lead connections.
    • Perform bridge calibration (short circuit, open circuit).
    • Ensure the component is properly discharged before testing.
    • Verify correct test frequency and level settings.
  • Проблеми са приказом: Adjust backlight brightness if the screen is too dim or bright.

7. Техничке спецификације

FeelTech ZT-DQ01 LCR Meter Specifications
ПараметарВредност/Распон
Број моделаZT-DQ01
Дисплаи2.8 инча пуног формата view angle color screen
Меасуремент ПараметерсL, C, R, Z, X, D, Q, θ, ESR
Опсег отпора0Ω - 20MΩ
Опсег капацитивности0pF - 100mF
Опсег индуктивности0nH - 100H
Тест фреквенције100Хз, 120Хз, 1КХз, 10КХз, 100КХз
Тест Левелс0.1В, 0.3В, 0.6В
Прецизностдо 0.3%
Батерија400мА литијумска батерија
Интерфејс за пуњењеУСБ Типе-Ц
Димензије146 к 30 к 18 мм
Тежина1 Kilogram (approx. 2.2 lbs)
ЦертификатиЦЕ, РоХС
FeelTech ZT-DQ01 LCR Meter technical specifications table

Image 6: Detailed technical specifications table for the ZT-DQ01 LCR Meter.

8. Пријаве

The FeelTech ZT-DQ01 LCR Meter is suitable for a wide range of applications, including:

  • Одржавање опреме
  • Scientific Research and Education
  • Тестирање производње
  • Electronic Engineering Development
FeelTech ZT-DQ01 LCR Meter showing various application scenarios

Image 7: Illustrates various applications of the ZT-DQ01 LCR Meter in different fields.

9. Гаранција и подршка

This product comes with a standard manufacturer's warranty. For warranty claims or technical support, please contact your retailer or the manufacturer directly. Please refer to your purchase documentation for specific warranty terms and contact information.

Трајање доступности резервних делова у ЕУ: 1 година.

FeelTech ZT-DQ01 Instruction Manual

© 2025 FeelTech. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.