1. Увод и крајview

This manual provides essential information for the installation, operation, and maintenance of the ACE Ruckus ICX7550-24P-E2-R3 24-Port Gigabit PoE+ Switch. This high-performance 1U rack-mount managed switch offers 24 ports of 10/100/1000 Mbps PoE+ with a 1.2 kW power budget and two 40 Gigabit QSFP+ uplinks, along with a USB Type-C console. It is designed for enterprise campus, data center, and edge deployments, supporting IP phones, wireless access points, cameras, and IoT devices.

The ICX7550-24P-E2-R3 is built for high availability and scalability, featuring dual hot-swappable power supplies, redundant fans, and the ability to stack up to 12 switches. Its advanced Layer 2 and Layer 3 capabilities ensure secure, low-latency traffic for critical applications.

Фронт view of multiple ACE Ruckus ICX7550-24P-E2-R3 switches stacked

Слика 1: Предња страна view of ACE Ruckus ICX7550-24P-E2-R3 switches, showcasing 24 Gigabit PoE+ ports and 40G QSFP+ uplinks.

2. Кључне карактеристике

  • 24 Gigabit PoE+ Ports: Provides 10/100/1000 Mbps connectivity with Power over Ethernet Plus, supporting a 1.2 kW power budget for connected devices.
  • 40G QSFP+ Uplinks: Two integrated 40 Gigabit QSFP+ ports for high-speed backbone connections and flexible network architecture.
  • USB Type-C Console: Modern console interface for local management and configuration.
  • Advanced Layer 2/3 Switching: Supports static routing, Multi-Chassis Link Aggregation Group (MLAG), Quality of Service (QoS), Access Control Lists (ACLs), IGMP snooping, and multicast for robust network control.
  • Дизајн који се може слагати: Allows stacking of up to 12 Ruckus switches for unified management, hitless upgrades, and scalable network expansion.
  • Висока доступност: Equipped with dual hot-swappable power supplies and redundant fans to ensure continuous operation and minimize downtime.
  • Меморија: Features 4 GB RAM and 4 GB flash memory for efficient operation and storage of configurations.
  • TAA Compliance: Meets Trade Agreements Act requirements, suitable for government deployments.

3. Садржај пакета

Verify that all items are present and undamaged upon unpacking. If any items are missing or damaged, contact your reseller immediately.

  • ACE Ruckus ICX7550-24P-E2-R3 Switch Unit
  • Power Cords (quantity may vary based on region)
  • Rack Mount Kit (brackets, screws)
  • USB Type-C Console Cable
  • Documentation (e.g., Quick Start Guide, Safety Information)

4. Подешавање и инсталација

4.1 Физичка инсталација

  1. Монтажа на рацк: Securely attach the provided rack mount brackets to the switch using the included screws. Install the switch into a standard 19-inch equipment rack, ensuring adequate ventilation space around the unit.
  2. Разматрања животне средине: Ensure the installation environment meets the operating temperature and humidity requirements specified in the technical specifications. Avoid placing the switch near heat sources or in areas with excessive dust.

4.2 Прикључак за напајање

  1. Connect the power cords to the dual hot-swappable power supply units at the rear of the switch.
  2. Plug the other end of the power cords into grounded AC power outlets. The switch will power on automatically.

4.3 Мрежне везе

  1. Етернет уређаји: Connect your network devices (IP phones, wireless access points, cameras, computers) to the 24 Gigabit PoE+ ports using standard Ethernet cables.
  2. Уплинк везе: Use appropriate QSFP+ transceivers and fiber optic cables to connect the two 40G QSFP+ uplink ports to your core network or other switches.

4.4 Console Connection

  1. Connect the USB Type-C console cable from your management workstation to the USB-C console port on the switch for initial configuration and command-line interface (CLI) access.
Позади view of multiple ACE Ruckus ICX7550-24P-E2-R3 switches stacked, showing power supplies and fan modules

Слика 2: Задња страна view of ACE Ruckus ICX7550-24P-E2-R3 switches, highlighting the dual hot-swappable power supplies and fan modules.

5. Руковање прекидачем

5.1 Почетно укључивање

Once connected to power, the switch will initiate its boot sequence. Observe the system status LEDs on the front panel to confirm successful startup.

5.2 Приступ интерфејсу за управљање

  • Command-Line Interface (CLI): Access via the USB Type-C console port or remotely via SSH after initial network configuration.
  • Web- Управљање засновано на: Access the graphical user interface (GUI) by entering the switch's IP address into a web browser. The default IP address and login credentials can be found in the Quick Start Guide or product documentation.

5.3 Основна конфигурација

After accessing the management interface, perform essential configurations such as:

  • Setting the management IP address and subnet mask.
  • Configuring VLANs for network segmentation.
  • Enabling and configuring PoE settings for connected devices.
  • Setting up user accounts and access privileges.
  • Configuring time and date settings (NTP).

6. Одржавање

6.1 Ажурирања фирмвера

Regularly check the ACE or Ruckus Networks support website for the latest firmware versions. Updating the firmware ensures optimal performance, security, and access to new features. Follow the provided instructions carefully during the update process.

6.2 Cleaning and Environmental Care

  • Keep the switch and its surroundings clean and free of dust. Dust accumulation can impede airflow and lead to overheating.
  • Use a soft, dry cloth for cleaning the exterior. Do not use liquid or aerosol cleaners.
  • Ensure proper airflow by keeping ventilation openings clear.

6.3 Monitoring System Status

Regularly monitor the switch's health and performance through the management interface. Pay attention to system logs, port status, CPU utilization, and temperature readings to identify potential issues early.

КСНУМКС. Решавање проблема

This section provides basic troubleshooting steps for common issues. For more complex problems, refer to the comprehensive product documentation or contact technical support.

7.1 Проблеми са напајањем

  • Нема напајања: Verify that power cords are securely connected to both the switch and the power outlets. Check power outlet functionality.
  • Power Supply Failure: If one power supply fails, the other should maintain operation. Check the status LEDs for the power supplies. Replace faulty units if necessary.

7.2 Проблеми са мрежном повезивањем

  • Port Link Down: Check the Ethernet cable connection to the device and the switch port. Verify the device is powered on and functioning.
  • Нема приступа мрежи: Confirm IP address configuration, VLAN assignments, and routing settings. Check for IP address conflicts.

7.3 PoE Functionality Issues

  • Device Not Receiving Power: Ensure the connected device is PoE-compatible. Check PoE settings on the switch port. Verify the total PoE power budget is not exceeded.

7.4 Console Access Issues

  • Cannot Connect via USB-C: Ensure the correct USB driver is installed on your management workstation. Verify terminal emulator settings (e.g., baud rate, data bits, parity, stop bits).

8. Техничке спецификације

ФеатуреСпецификација
Број моделаICX7550-24P-E2-R3
Портс24 x 10/100/1000 Mbps PoE+
Уплинк портови2 x 40G QSFP+
ПоЕ буџет за напајање1.2 kW (1123.7 W max draw)
Конзолни портУСБ Типе-Ц
РАМ4 ГБ
Фласх меморија4 ГБ
Форм Фацтор1У носач за носач
Повер СупплиесDual Hot-Swappable
Компатибилни уређајиWi-Fi & Ethernet Devices
ПроизвођачRUCKUS & ACE
УПЦ199240108239
Датум првог доступног14. августа 2025. године

9. Гаранција и подршка

For technical support, warranty information, or service requests, please refer to the official ACE or Ruckus Networks website or contact your authorized reseller. Keep your purchase receipt and product serial number readily available when seeking support.

© 2025 ACE. All rights reserved. Ruckus is a trademark of CommScope, Inc.

Повезани документи - ICX7550-24P-E2-R3

Преview Упутство за употребу и техничке спецификације Yuanley PoE прекидача
Ово корисничко упутство и документ са техничким спецификацијама пружају детаљне информације о Yuanley PoE прекидачима, укључујући сценарије примене, објашњења предњег панела и свеобухватне техничке параметре за различите моделе.
Преview INTELBRAS WC 7060 Series Access Controllers: Hardware Information and Specifications
Detailed hardware information, technical specifications, ports, and LED descriptions for the INTELBRAS WC 7060 Series Access Controllers. Includes removable components, power supplies, fan trays, and expansion modules.
Преview AirLive POE-GSH420-60 Quick Setup Guide: 6-Port Gigabit PoE+ Switch
This quick setup guide provides installation instructions and details on indicator lights and function switches for the AirLive POE-GSH420-60 6-Port Gigabit PoE+ Switch. It also mentions the related POE-GSH802M model.
Преview NETGEAR 24-Port Gigabit Ethernet PoE+ Smart Switch Installation Guide (GS724TPv3, GS724TPPv3)
This installation guide provides instructions for setting up and managing NETGEAR 24-Port Gigabit Ethernet PoE+ Smart Switches, models GS724TPv3 and GS724TPPv3. It covers package contents, connection steps, PoE status checks, switch discovery and management methods (NETGEAR Discovery Tool, device UI, NETGEAR Insight), PoE considerations, and troubleshooting.
Преview NICGIGA PoE прекидач - корисничко упутство V4.0 - Техничке спецификације и карактеристике
Корисничко упутство за NICGIGA PoE прекидаче (V4.0), са детаљним описом сценарија примене, објашњењима предњег панела и свеобухватним техничким спецификацијама за моделе, укључујући GS0410P, FS0820GP, GS0800P, AI-FS1621GP, GS1620P, FS2420GP, NIC-S25-0402P и NIC-S25-0801P.
Преview Водич за модуле примопредајника мрежних адаптера FS: Примопредајници, DAC-ови и AOC-ови за Intel мрежне картице
Свеобухватни водич који детаљно описује компатибилност FS примопредајника, DAC-ова и AOC-ова са мрежним картицама заснованим на Intel-у. Садржи листе подржаних модула и каблова за различите моделе мрежних адаптера.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.