MIWA AUR.CS

MIWA AUR.CS Backset 76mm Electric Lock Case Instruction Manual

Model: AUR.CS

1. Увод

This instruction manual provides essential information for the proper installation, operation, and maintenance of the MIWA AUR.CS Backset 76mm Electric Lock Case. Please read this manual thoroughly before proceeding with any procedures to ensure safe and correct usage. This product is designed for specific door applications and requires careful handling.

2. Производ је готовview

The MIWA AUR.CS is an electric lock case designed for secure door applications. It features a 76mm backset and is part of the AU series, compatible with AUT, AUR, AUTA, and AURA systems. The lock case includes a function switching type electric mechanism and is identifiable by the AU26 engraving.

Кључне карактеристике:

  • Назив производа: AUR Lock Case Body
  • Бацксет: 76мм
  • Гравирање: 02 MIWA AU26
  • Тип: Function Switching Electric Lock Case
MIWA AUR.CS Electric Lock Case with wiring harness and faceplate

Слика 2.1: Фронт view of the MIWA AUR.CS electric lock case, showing the internal mechanism, wiring harness, and a separate faceplate. The wiring is color-coded for electrical connections.

MIWA AUR.CS Electric Lock Case with faceplate attached

Слика 2.2: Одозго надоле view of the MIWA AUR.CS electric lock case with the faceplate attached. This view highlights the overall assembly and mounting points.

Сиде view of MIWA AUR.CS Electric Lock Case

Слика 2.3: Сиде view of the MIWA AUR.CS electric lock case, illustrating its profile and the position of the latch bolt and deadbolt mechanisms. The model number and other markings are visible on the side.

Close-up of MIWA AU26 engraving on faceplate

Слика 2.4: Детаљно view of the faceplate, clearly showing the "MIWA AU26" engraving, which identifies the specific model and series of the lock case.

3. Спецификације

СпецификацијаДетаљ
БрандМИВА
Број модела производаAUR.CS
Димензије производа (ДкШкВ)24 к 2.5 к 9.5 цм
БојаST (Silver)
Бацксет76мм
Гравирање02 MIWA AU26
Укључене компонентеNone (Lock case body only)
Произвођачmiwa

4. Подешавање и инсталација

Installation of the MIWA AUR.CS electric lock case requires precision and knowledge of door hardware and electrical wiring. It is highly recommended that installation be performed by a qualified professional to ensure proper function, security, and compliance with local building codes.

Општа упутства за инсталацију:

  1. Припрема: Ensure the door is properly prepared with the correct mortise cutout for the lock case and faceplate. Verify the backset measurement (76mm) matches the door preparation.
  2. Mounting the Lock Case: Insert the lock case into the mortise cutout in the door edge. Secure it with appropriate screws through the mounting holes on the faceplate.
  3. Ожичење: Connect the electrical wiring harness (as shown in Figure 2.1) to the door's power supply and access control system according to the system's wiring diagram. Pay close attention to polarity and ensure all connections are secure and insulated.
  4. Cylinder and Trim Installation: Install the appropriate door cylinder, handles, and trim plates as per their respective instructions. Ensure they operate smoothly with the lock case mechanism.
  5. Уградња заштитне плоче: Install the strike plate on the door frame, aligning it precisely with the latch bolt and deadbolt of the lock case.
  6. тестирање: After installation, thoroughly test all functions of the lock, including electrical operation, manual key override, and handle operation, before final use.

Refer to the specific wiring diagrams provided with your access control system for detailed electrical connections. Incorrect wiring can damage the lock case or the access control system.

5. Операција

The MIWA AUR.CS electric lock case operates in conjunction with an external access control system. Its function switching type allows for various operational modes depending on the system configuration.

Основна операција:

  • Unlocking Electrically: When an authorized signal is received from the access control system, the electric mechanism will retract the latch bolt or deadbolt, allowing the door to be opened.
  • Locking Electrically: Upon door closure or removal of the authorization signal, the lock case will automatically secure the door, extending the latch bolt or deadbolt.
  • Ручно замена: In case of power failure or emergency, the lock can typically be operated manually using a key from the outside or a thumbturn/lever from the inside, depending on the specific trim installed.
  • Промена функција: The lock case supports different operational modes (e.g., fail-safe, fail-secure) which are configured via the access control system. Consult your system's manual for details on setting these functions.

Always ensure the door closes completely for the lock to engage properly. Do not force the door if the lock mechanism is not fully retracted.

6. Одржавање

Regular maintenance helps ensure the longevity and reliable operation of your MIWA AUR.CS electric lock case.

Процедуре одржавања:

  • Чишћење: Keep the faceplate and surrounding areas clean from dust and debris. Use a soft, dry cloth. Avoid abrasive cleaners or solvents that could damage the finish.
  • подмазивање: Periodically (e.g., annually) apply a small amount of silicone-based lubricant to the latch bolt and deadbolt mechanisms to ensure smooth operation. Do not over-lubricate. Avoid oil-based lubricants as they can attract dirt.
  • инспекција: Regularly inspect the lock case, faceplate, and strike plate for any signs of wear, damage, or misalignment. Check that all screws are tight.
  • Провера ожичења: If accessible, periodically check the electrical connections for any signs of corrosion or loose wiring. This should only be done by qualified personnel with power disconnected.
  • Тест функције: Routinely test the lock's electrical and manual functions to confirm proper operation.

If you notice any significant issues or damage, contact a qualified technician for repair or replacement.

КСНУМКС. Решавање проблема

This section addresses common issues you might encounter with the MIWA AUR.CS electric lock case.

ПроблемМогући узрокРешење
Lock does not engage/disengage electrically.No power, faulty wiring, access control system issue, damaged solenoid.Check power supply to the lock. Verify wiring connections. Consult access control system manual. Contact a technician if solenoid is suspected.
Door does not close properly or latch bolt binds.Misaligned strike plate, door sag, debris in mortise.Adjust strike plate alignment. Check door hinges. Clean mortise area.
Key/thumbturn operation is stiff.Lack of lubrication, internal debris, worn cylinder.Apply silicone lubricant to the mechanism. Clean out any debris. If worn, consider cylinder replacement.
Неуобичајени звукови током рада.Internal wear, loose components, foreign object.Inspect for loose screws or components. If noise persists, professional inspection is recommended.

For issues not listed here or if solutions do not resolve the problem, contact a qualified locksmith or the product manufacturer for assistance.

8. Гаранција и подршка

Warranty information for the MIWA AUR.CS electric lock case is typically provided by the seller or manufacturer at the time of purchase. Please retain your proof of purchase for warranty claims.

For technical support, service, or to inquire about replacement parts, please contact your authorized MIWA dealer or the point of purchase. Provide them with the product model number (AUR.CS) and any relevant details about your issue.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.