1. Увод

This user manual provides detailed instructions for the safe and effective operation of your Hcalory TS-M Thermal Imaging Camera with Multimeter. This device integrates thermal imaging capabilities with a professional-grade digital multimeter, offering a versatile tool for diagnostics and measurement in various applications. Please read this manual thoroughly before using the device and retain it for future reference.

2. Безбедносне информације

Always observe the following safety precautions to prevent injury and avoid damage to the instrument or the equipment under test.

  • Do not use the device if it appears damaged or if the insulation on the test leads is compromised.
  • Ensure the correct function and range are selected before making any measurements.
  • Не прекорачујте максималне границе уноса за било коју функцију.
  • Будите изузетно опрезни када радите са волtagизнад 30V AC RMS, 42V вршне струје или 60V DC. Ови напониtagпредстављају опасност од удара.
  • Disconnect power to the circuit and discharge all high-voltage capacitors before performing resistance, continuity, or diode tests.
  • Use only the test leads provided or approved by Hcalory.
  • Држите прсте иза заштитника за прсте на тест сондама током употребе.
  • Do not operate the device in explosive gas, vapor, or dust environments.
  • Refer to the specifications section for detailed electrical ratings and environmental conditions.

3. Садржај пакета

Verify that all items listed below are present and undamaged upon opening the package. If any item is missing or damaged, contact your retailer.

Contents of Hcalory TS-M package including thermal imager, manual, cables, probes, and case.

Слика 3.1: Садржај пакета
The image displays the complete contents of the Hcalory TS-M package. These include (1) an EV Toolkit (carrying case), (2) the Instruction Manual, (3) a USB Charging Cable/Probe, (4) the Thermal Imaging Multimeter 2-in-1 device, (5) Multimeter Probes, and (6) a Macro Magnetic Lens.

  1. Thermal Imaging Multimeter (Model TS-M)
  2. Multimeter Test Leads (Probes)
  3. УСБ кабл за пуњење
  4. Macro Magnetic Lens
  5. Упутство за употребу
  6. Carrying Case (EV Toolkit)

4. Производ је готовview

The Hcalory TS-M combines a high-resolution thermal imager with a full-function digital multimeter, designed for efficiency and accuracy in various diagnostic tasks. Its robust construction ensures durability in demanding environments.

Предње и задње view of the Hcalory TS-M Thermal Imaging Multimeter.

Figure 4.1: Device Front and Back View
This image shows the Hcalory TS-M device from both the front and back. The front features the display screen, control buttons, and multimeter input jacks. The back includes the IR camera lens and a macro lens attachment point.

Кључне карактеристике:

  • Integrated Thermal Imaging: High-resolution thermal sensor for visualizing temperature differences.
  • Professional Multimeter: Full range of electrical measurement functions including voltagе, струја, отпорност, континуитет и испитивање диода.
  • TISR Resolution: Enhanced thermal imaging resolution of 240x240 pixels for clearer thermal details.
  • Macro Lens Capability: Magnetic macro lens for detailed thermal inspection of small components.
  • Робустан дизајн: Built to withstand drops, dust, and water splashes, suitable for tough job sites.
  • Дуг век трајања батерије: 1500 mAh battery providing up to 7 hours of continuous operation.

5. Подешавање

5.1 Пуњење уређаја

Before first use, fully charge the Hcalory TS-M. Connect the provided USB charging cable to the device's USB-C port and to a standard USB power adapter (not included) or a computer USB port. The charging indicator on the device will show charging status.

Hcalory TS-M device connected to a charger, showing battery icon and 7 hours of battery life.

Слика 5.1: Пуњење уређаја
The image illustrates the Hcalory TS-M connected via its USB-C port for charging. The display indicates a full battery and an estimated operational time of 7 hours, powered by its 1500 mAh battery.

5.2 Прикључивање мерних каблова

For multimeter functions, insert the red test lead into the VΩ(+) jack and the black test lead into the COM(-) jack. Ensure a secure connection.

5.3 Attaching Macro Lens (Optional)

For detailed thermal inspection of small components, attach the magnetic macro lens to the designated area on the back of the device, over the IR camera lens. The magnetic attachment ensures easy installation and removal.

Hcalory TS-M with a magnetic macro lens attached, showing magnified thermal images.

Figure 5.2: Macro Lens Attachment
This image demonstrates the Hcalory TS-M with its magnetic macro lens attached to the rear. The display shows a comparison of thermal images, highlighting the enhanced detail provided by the 5x magnification of the macro lens compared to 1x without it, useful for pinpoint accuracy on small components.

6. Упутство за употребу

6.1 Укључивање/искључивање

Press and hold the power button (usually marked with a circle and a vertical line) to turn the device on or off.

6.2 Thermal Imaging Mode

Upon powering on, the device typically defaults to thermal imaging mode. The screen will display a thermal image of the environment. Use the navigation buttons (up, down, left, right, OK) to access menus and adjust settings such as color palettes, emissivity, and temperature units.

User holding Hcalory TS-M, displaying a thermal image of an engine.

Figure 6.1: Thermal Imaging in Use
The image shows a user holding the Hcalory TS-M, with its screen displaying a thermal image of an engine. This illustrates the device's capability to provide immediate visual temperature data, aiding in quick problem diagnosis.

6.2.1 TISR Resolution Enhancement

The Hcalory TS-M features TISR (Thermal Imaging Super Resolution) technology, enhancing the thermal image resolution to 240x240 pixels for greater clarity. This feature can typically be toggled on or off via the device's menu settings to suit different inspection needs.

Comparison of thermal images with TISR on (240x240) and TISR off (64x64).

Figure 6.2: TISR Resolution Comparison
This image demonstrates the impact of TISR technology. On the left, a thermal image with TISR enabled shows a resolution of 240x240, providing significantly more detail. On the right, the same scene with TISR off displays a lower resolution of 64x64, highlighting the clarity improvement offered by the enhanced resolution feature.

6.3 Режим мултиметра

To switch to multimeter mode, use the mode selection button or navigate through the menu. Once in multimeter mode, select the desired measurement function (e.g., AC Voltagе, ДЦ Волtage, Resistance, Continuity, Diode Test) using the function dial or buttons. Connect the test leads to the circuit under test as appropriate for the selected function.

Hcalory TS-M with multimeter probes connected to a circuit board.

Figure 6.3: Multimeter Functionality
The image shows the Hcalory TS-M in use as a multimeter, with its probes connected to a circuit board. The screen displays electrical measurement readings, demonstrating its capability for precise electrical diagnostics.

6.3.1 Common Multimeter Functions:

  • Волtage Measurement (AC/DC): Connect probes in parallel with the component or circuit to measure voltage.
  • Мерење отпора: Ensure the circuit is de-energized. Connect probes across the component to measure resistance.
  • Тест континуитета: For checking if a circuit is complete. The device will typically emit an audible tone if continuity is detected.
  • Тест диода: За проверу функционалности диода.

7. Одржавање

7.1 Чишћење

Wipe the device casinг са огласомamp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any power source before cleaning. Do not immerse the device in water.

7.2 Одржавање батерије

The device contains a rechargeable lithium-ion battery. For optimal battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge it to approximately 50% every few months.

7.3 Fuse Replacement (Multimeter)

The multimeter functions are protected by internal fuses. If a current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Fuse replacement should only be performed by qualified personnel.

КСНУМКС. Решавање проблема

ПроблемМогући узрокРешење
Уређај се не укључује.Слаба или испражњена батерија.Напуните уређај помоћу приложеног УСБ кабла.
Термална слика је мутна или нејасна.Lens is dirty; TISR is off.Clean the IR lens with a soft cloth. Enable TISR in settings.
Multimeter readings are incorrect or zero.Incorrect function selected; test leads not properly connected; blown fuse.Verify function selection. Ensure leads are securely connected. Check and replace fuse if necessary (qualified personnel only).
Уређај се замрзава или престаје да реагује.Софтверски квар.Perform a soft reset by holding the power button for 10-15 seconds. If persistent, a factory reset may be required (refer to advanced settings).

9. Спецификације

ФеатуреСпецификација
МоделТС-М
БрандХКАЛОРИЈА
Тхермал Ресолутион240x240 pixels (with TISR)
Температурни опсег-68°F to 1022°F (approximately -55°C to 550°C)
Тип батерије12V Lithium-ion (included)
Капацитет батерије1500 mAh (5.55 ват-сати)
Оперативно времеДо 7 сати
Тежина артикла599 г
Димензије пакета24.41 к 15.09 к 6.71 цм
Функције мултиметраВолtage (AC/DC), Current, Resistance, Continuity, Diode Test
Укључене компонентеThermal Imaging Camera with Multimeter, Test Leads, USB Cable, Macro Lens, Carrying Case, Manual
Земља пореклаКина

10. Гаранција и подршка

For warranty information and technical support, please refer to the warranty card included with your product or visit the official Hcalory webсајт. Сачувајте рачун као доказ о куповини за потребе гаранције.

In case of issues not covered in the troubleshooting section, or for service inquiries, please contact Hcalory customer support.

© 2025 HCALORY. Сва права задржана.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.