SINOTIMER STVP936-1-80A

User Manual: Three-Phase Adjustable Over/Under Voltagе Протецтор

Model: STVP936-1-80A

1. Увод

The SINOTIMER STVP series automatic over-voltagе и под-волtage protector is designed for three-phase 3*127V/220VAC power systems with a rated working current of 80A. This device provides essential protection for electrical equipment by instantaneously cutting off the power supply when over-voltagе, под-волtage, or over-current conditions are detected. Once the circuit voltage returns to normal, the protector automatically restores power, ensuring continuous operation and safeguarding your appliances from damage.

This protector integrates multiple protection functions including over-voltagе, под-волtage, over-current, three-phase current (voltage) imbalance, phase sequence (reverse phase), zero-break, and phase-break protection. It also features voltmeter and ammeter functions, and the ability to restore factory settings. The device offers comprehensive features, stable performance, and ease of operation.

Детаљно упутство за употребу у PDF формату је доступно за преузимање: Упутство за употребу (ПДФ)

2. Кључне карактеристике

  • Овер-волtagе заштита
  • Ундер-волtagе заштита
  • Заштита од прекомерне струје
  • Аутоматски опоравак
  • Волtage display (separate ABC phase voltagе мерење)
  • Ampere display (separate ABC phase ampere measurement)
  • Трофазни ampere unbalance protection
  • Phase sequence protection (reverse phase protection)
  • Zero line break protection
  • Заштита од прекида фазе
  • Fault inquiry function
  • Rotation display of voltage and current for each phase
  • Adjustable over-voltage protection value and recovery value
  • Adjustable under-voltage protection value and recovery value
  • Adjustable over-current protection value and action time
  • Adjustable 3-phase ampere unbalance protection value and action time
  • Adjustable delay time after power-on
  • Подесиво време кашњења опоравка од грешке
  • Factory data reset function

3. Спецификације производа

АтрибутВалуе
Број моделаSTVP936-1-80A
Повер Суппли3*127V/220VAC 60Hz
Ратед Волtage220В
ФазаТри фазе
Макс. Струја оптерећења1~80A Adjustable (default: 80A)
Овер-волtagе Заштитни опсег121V-150V-OFF Adjustable (default: 140V)
Овер-волtagе Опсег опоравка120V-149V (default: 135V)
Овер-волtage Action Time0.1~10 seconds (default: 0.2s)
Ундер-волtagе Заштитни опсег118V-80V-OFF Adjustable (default: 90V)
Ундер-волtagе Опсег опоравка118V-91V (default: 95V)
Ундер-волtage Action Time0.1~10 seconds (default: 0.2s)
3-Phase Volt Unbalance Protection10%~50%~OFF (default: 20%)
3-Phase Volt Unbalance Action Time0.1~10 seconds (default: 1s)
Delay Time After Power-on2~255 seconds (default: 2s)
Време кашњења опоравка од грешке2~600 seconds (default: 60s)
Приказ моделаЛЦД
Димензије71.5mm (W) * 95.2mm (H) * 65.7mm (D)
Инсталација35 мм ДИН шина
ЦертифицатионЦЕ, РоХС

4. Безбедносне информације

  • Инсталацију и одржавање треба да обављају само квалификовани електричари.
  • Ensure the power supply is disconnected before any installation or wiring work.
  • The device does not provide overload or short-circuit protection. It must be used in conjunction with appropriate external circuit breakers (e.g., C45, C65 mini circuit breakers) for comprehensive protection.
  • Проверите да ли су сви спојеви ожичења безбедни и исправни пре него што укључите напајање.
  • Do not operate the device in wet or hazardous environments.

5. Инсталација

5.1 Физичке димензије

Dimensions of the STVP936-1-80A protector, showing width 71.5mm, height 95.2mm, and depth 65.7mm.
Слика 1: Димензије производа

5.2 Монтажа

The protector is designed for 35mm DIN rail installation. Snap the device onto the DIN rail securely.

Сиде view of the protector showing its compatibility with a DIN rail for mounting.
Figure 2: DIN Rail Mounting

5.3 Дијаграм ожичења

Connect the input and output terminals as shown in the diagram below. Ensure correct phase (L1, L2, L3) and neutral (N) connections. The input terminals are located at the top, and output terminals at the bottom.

Фронт view of the protector with input (N, L1, L2, L3) and output (N, L1, L2, L3) terminals clearly labeled with arrows.
Figure 3: Input/Output Terminal Labels
Detailed wiring diagram showing connections from a power switch to the voltage protector (IN terminals) and from the voltage protector (OUT terminals) to an air circuit breaker.
Figure 4: General Wiring Diagram

6. Подешавање и конфигурација

Да бисте ушли у режим подешавања, притисните и држите СЕТ button for 3 seconds. Then, continuously press СЕТ to cycle through the parameters. Use the и buttons to adjust the values. When "ENd" appears, press СЕТ again to save the data and exit the setting mode.

If no operation is performed within 10 seconds after pressing СЕТ, the device will automatically exit the setting mode, and any unsaved changes will be lost.

6.1 Parameter Settings Table

КоракСадржајЛЦД екранDescription / Range (Default)
1Овер-волtagе вредност заштитеUvo 280V221V-300V-OFF (280V)
2Овер-волtagе повратна вредностUvor 250V220В-299В (250В)
3Овер-волtage protection action time0.2С0.1-10с (0.2с)
4Ундер-волtagе вредност заштитеUve 160V219V-150V-OFF (160V)
5Ундер-волtagе повратна вредностUver 180V151В-220В (180В)
6Ундер-волtage protection action time0.2С0.1-10с (0.2с)
7Вредност заштите од прекомерне струје>In 80A1-80А (80А)
8Over-current protection action time5S1-512с (5с)
93 фаза amp unbalance protection value>In %5%-90%-OFF (25%). Not active if current < 2A.
103 фаза amp unbalance protection action time1.0 С0.1-10с (1с)
11Заштита редоследа фазаON ABCON or OFF (ON)
12Време одлагања укључивања2 С2-255с (2с)
13Fault recovery delay time60 С2-512с (60с)
14Fault inquiry codeE0Press ▲ to view last 5 fault records (E1-E5). >U for overvoltage, <U for undervoltage.
15КрајКрајPress SET to save and exit.

6.2 Ресетовање на фабричка подешавања

To reset the device to factory settings, press and hold the и тастери истовремено 3 секунде.

7. Операција

Once installed and configured, the device will continuously monitor the three-phase power supply. The LCD screen will automatically rotate to display the real-time voltage and current for each phase (L1, L2, L3).

У случају преко-волtagе, под-волtage, or over-current event, the protector will automatically trip and cut off the power supply to protect connected equipment. After the fault condition clears and the recovery delay time has passed, the device will automatically restore power.

КСНУМКС. Решавање проблема

8.1 Fault Inquiry

If a fault occurs, the device will display an error code (E0). You can press the button to query the last 5 fault records (E1-E5). The display will indicate:

  • ">U" for overvoltagе догађаји.
  • "<U" for undervoltagе догађаји.

8.2 Phase Sequence Error

If the LCD displays "ABC" character, it indicates a phase sequence error. To correct this, arbitrarily reverse any two of the three phase lines (L1, L2, L3) at the input.

9. Одржавање

  • Држите уређај чистим и без прашине и влаге.
  • Редовно проверавајте спојеве ожичења да ли постоје затегнутост и знаци хабања или оштећења.
  • Do not attempt to repair the device yourself. Refer to qualified personnel for service.

10. Гаранција и подршка

For technical support, inquiries, or warranty claims, please contact the distributor:

Дистрибутер: XNY INTERNATIONAL LIMITED

Адреса: Room 20A, Kiu Fu Commercial Building, 300 Lockhart Road, Wanchai, Hong Kong.

Тел: 0086 57761733853

факс: 0086 577 89736991

ВхатсАпп: 0086 1565857 3377

Вецхат: sinotimer

Скипе: sinotimer

Web: ввв.синотимер.цом

Емаил: info@sinotimer.com

Documents - SINOTIMER – STVP936-1-80A

нема релевантних докумената