This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SANDISOLAR 3KW 24V 110V/120V Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.

1.1 Производ завршенview

The SANDISOLAR SD-HYM-2430HW-US is an off-grid pure sine wave solar inverter designed for various applications, including power generation systems, household use, and PV roof installations. It features a built-in 100A MPPT solar charger and WiFi for remote monitoring.

SANDISOLAR 3KW 24V Solar Inverter with key specifications
Figure 1.1: SANDISOLAR 3KW 24V Solar Inverter highlighting 3KW 24V, 110VAC, 5000W Max PV Array Power, 100A Max Solar Charge Current, 500VDC Max PV Circuit Voltage, and Built-in WiFi.

1.2 Кључне карактеристике

  • Чисти синусни излаз за осетљиву електронику.
  • Built-in MPPT 100A solar charger for efficient solar energy harvesting.
  • Мак ПВ Инпут Волtagе од 500Вдц.
  • Integrated WiFi for remote monitoring and control via the SmartESS App.
  • Capable of working without a battery.
  • Dual output for smart load management.
  • Detachable dust cover for protection in harsh environments.
  • Compatible with LiFePO4 batteries via RS485 communication.
  • Lithium battery activation function via PV or Utility.
  • Supports multiple output priorities: UTL (Utility), SOL (Solar), SBU (Solar-Battery-Utility), SUB (Solar-Utility-Battery).
  • EQ (Equalization) function to optimize battery performance and extend lifecycle.
Diagram showing 100A MPPT technology and other inverter features
Figure 1.2: Visual representation of key inverter features including 100A MPPT, Pure Sine Wave, PV 60-500Vdc, Lithium Battery Activation, Anti-shock Design, Dual Outputs, WiFi, and RS485.

1.3 Сценарији примене

Images depicting various application scenarios for the solar inverter
Слика 1.3: Прamples of inverter applications including power generation systems, household use, PV roof installations, indoor areas, and farms.

2. Безбедносна упозорења

УПОЗОРЕЊЕ: Опасност од удара

Инсталација се мора обавити пажљиво због велике запремине батеријеtagе у серији.

ОПРЕЗ!!

  • Do not place anything between the flat part of the inverter terminal. Otherwise, overheating may occur.
  • Немојте наносити антиоксидантну супстанцу на терминале пре него што су терминали чврсто повезани.
  • Пре него што направите коначну једносмерну везу или затворите ДЦ прекидач/растављач, уверите се да позитивни (+) морају бити повезани са позитивним (+) и негативни (-) морају бити повезани на минус (-).
  • ПОГОДНО ЗА МОНТАЖУ САМО НА БЕТОН ИЛИ ДРУГУ НЕЗАПАЉИВУ ПОВРШИНУ.

3. Распакивање и преглед

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:

Видео 3.1: Распакивање и иницијалиview of the SANDISOLAR solar inverter.

4. Инсталација

4.1 Припрема

Before connecting all wirings, please remove the bottom cover by unscrewing two screws.

4.2 Монтажа јединице

Consider the following points when selecting the installation location:

  1. Не монтирајте претварач на запаљиве грађевинске материјале.
  2. Монтирајте на чврсту површину.
  3. Инсталирајте овај инвертор у висини очију како би се ЛЦД екран могао читати у сваком тренутку.
  4. Температура околине треба да буде између 0°Ц и 55°Ц да би се обезбедио оптималан рад.
  5. The recommended installation position is vertically on the wall.
  6. Ensure sufficient clearance around the unit for heat dissipation and wire routing, as shown in the diagram below.
Product dimensions and mounting clearances
Figure 4.1: Product dimensions (350mm H, 313mm W, 115mm D) and recommended clearances for mounting.

Монтирајте уређај завртањем три завртња. Препоручује се употреба завртња М4 или М5.

4.3 Повезивање батерије

ОПРЕЗ:

For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the typical amperage in the table below for required fuse or breaker size.

УПОЗОРЕЊЕ!

All wiring must be performed by qualified personnel. It is critical for system safety and efficient operation to use appropriate cables for battery connection. To reduce risk of injury, use the proper recommended cable and terminals.

Recommended Battery Cable & Terminal Size (3KVA Model)
МоделМаксимум AmpерагеКапацитет батеријеВеличина жицеКабл mm²Terminal Size L(mm)Terminal Size W(mm)Terminal Size D(mm)Вредност обртног момента
3КВА137А200АХ2АВГ353715.36.44~6 Нм

Пратите ове кораке да бисте повезали батерију:

  1. Create battery positive and negative cables according to the recommended specifications.
  2. Повежите све батерије по потреби.
  3. Insert battery cables flatly into the inverter's battery connector and ensure bolts are tightened with a torque of 4~6 Nm. Verify correct polarity at both the battery and the inverter/charger.

4.4 Улазно/излазно повезивање наизменичне струје

ОПРЕЗ!!

Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is fully protected from overcurrent. The recommended AC breaker specification is 50A. There are two terminal blocks marked “IN” and “OUT”; do NOT mis-connect input and output connectors.

УПОЗОРЕЊЕ!

All wiring must be performed by qualified personnel. It is crucial for system safety and efficient operation to use appropriate cables for AC input connection. To reduce risk of injury, use the proper recommended cable size.

Suggested Cable Requirement for AC Wires (3KVA Model)
МоделГаугеВредност обртног момента
3КВА10АВГ1.4~1.6 Нм

Follow these steps to connect AC input/output:

  1. Пре него што направите AC улазне/излазне везе, уверите се да је DC заштитни прстен или растављач отворен.
  2. Уклоните 10 мм изолационе омотаче за шест проводника. Скратите фазни L и неутрални проводник N за 3 мм.
  3. Insert AC input wires according to the polarities indicated on the terminal block and tighten the screws. Connect the PE protective conductor (➔Ground (yellow-green)) first.
  4. Insert AC output wires according to the polarities indicated on the terminal block and tighten the screws. Connect the PE protective conductor (➔Ground (yellow-green)) first.
  5. Уверите се да су све жице безбедно повезане.

ОПРЕЗ: Важно

Ensure AC wires are connected with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuiting when inverters operate in parallel. Appliances like air conditioners require 2-3 minutes to restart to balance refrigerant gas. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function before installation.

4.5 ПВ прикључак

ОПРЕЗ:

Пре повезивања са PV модулима, инсталирајте посебан DC прекидач између инвертора и PV модула.

УПОЗОРЕЊЕ!

All wiring must be performed by qualified personnel. It is very important for system safety and efficient operation to use appropriate cables for PV module connection. To reduce risk of injury, use the proper recommended cable size.

Recommended PV Cable & Terminal Size (3KVA Model)
МоделТипично AmpерагеВеличина каблаОбртни момент
3КВА27А10 АВГ1.4~1.6 Нм

Избор ПВ модула:

When selecting PV modules, consider these parameters:

  1. Отворено коло Волtage (Voc) PV модула не сме прећи максималну вол. отвореног кола PV низаtagе инвертора.
  2. Отворено коло Волtage (Voc) PV модула треба да буде већи од минималног напона батеријеtage.
Solar Charging Mode Specifications (3KVA Model)
ИНВЕРТЕР МОДЕЛ3КВА
Макс. ПВ Арраи Опен Цирцуит Волtage500ВДЦ
ПВ Арраи МППТ Волtagе Распон60ВДЦ~500ВДЦ
Макс. ПВ УЛАЗНА СТРУЈА27А

Follow these steps for PV module wire connection:

  1. Уклоните 6 мм изолационе чауре за позитивне и негативне проводнике.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive pole (+) to positive pole (+) of PV input connector, and negative pole (-) to negative pole (-) of PV input connector.
  3. Уверите се да су све жице безбедно повезане.

4.6 Завршна скупштина

After connecting all wirings, replace the bottom cover by screwing the two screws back into place.

Diagram showing solar panels connected to the inverter and battery, powering household loads.
Figure 4.2: System connection diagram illustrating PV panels, inverter, battery, and various household loads.

5. Операција

5.1 Укључивање/искључивање напајања

Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the side of the case) to turn on the unit.

Сиде view of the inverter showing the power on/off switch and dry contact port.
Слика 5.1: Страна view of the inverter, indicating the Power On/Off switch (14) and Dry contact port (13).

5.2 Плоча за рад и екран

The front panel of the inverter includes an LCD display, three indicators, and four function keys, providing operating status and input/output power information.

Front panel of the inverter with LCD display, status indicators, and function buttons.
Figure 5.2: Front panel of the inverter, detailing the LCD Display (1), Status Indicator (2), Charging Indicator (3), Fault Indicator (4), and Function Buttons (5).
Rear panel of the inverter showing various connection ports.
Figure 5.3: Rear panel of the inverter, detailing Battery Input (6), RS485 Communication Port (7), Grounding (8), WiFi Antenna Port (9), AC Input (10), AC Output (11), and PV Input (12).
Поруке ЛЕД индикатора
ЛЕД индикаторБојаПоруке
АЦ/ИНВЗеленаНепрекидно светли: Излаз се напаја из мреже у линијском режиму.
Трепће: Излаз се напаја батеријом или фотонапонским системима у режиму рада на батерије.
ЦХГЗеленаSolid On: Battery is fully charged.
Трепће: Батерија се пуни.
ГРЕШКАЦрвениНепрекидно светли: Дошло је до квара у инвертору.
Трепће: У инвертору се јавља упозорење.
Опис функцијских тастера
Функцијски тастерОпис
ЕСЦЗа излазак из режима подешавања.
UPTo go to previous selection.
ДОВНTo go to next selection.
ЕНТЕРTo confirm the selection in setting mode or enter setting mode.

5.3 ЛЦД подешавање

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" buttons to select setting programs, then press "ENTER" to confirm or "ESC" to exit.

The LCD settings allow configuration of various parameters, including output source priority, maximum charging current, AC input voltage range, battery type, auto-restart options, output voltage, output frequency, auto bypass, and various battery charging and equalization settings. Refer to the detailed tables in the PDF user manual for specific program numbers and options.

5.4 Setting for Lithium Battery

If using a lithium battery with the inverter, ensure it is a compatible type. There are two connectors on the lithium battery: an RS485 port for BMS communication and a power cable.

Lithium Battery Connection:

  1. Assemble battery terminals based on recommended cable and terminal size (refer to Lead-acid Battery connection section for details).
  2. Повежите RS485 порт батерије са BMS (RS485) комуникационим портом инвертора.

Комуникација и подешавање литијумске батерије:

Ensure the BMS communication cable is connected between the battery and inverter. This cable facilitates information and signal exchange, allowing the inverter to:

  • Поново конфигуришите обим пуњењаtagе, струја пуњења и гранична запремина пражњења батеријеtage based on lithium battery parameters.
  • Start or stop charging according to the lithium battery status.

The communication cable is typically included in the package. Ensure the lithium battery RS485 port connects pin-to-pin to the inverter's RS485 port. Refer to the PDF user manual for pin assignments.

Setting for PYLON US2000 Lithium Battery:

For PYLONTECH US2000 lithium batteries, configure the Dip Switches for baud rate and battery group address. Dip switch position 'OFF' means '0', and 'ON' means '1'. Dip 1 'ON' sets the baud rate to 9600. Dips 2, 3, and 4 are reserved for battery group address on the master battery.

Процес инсталације:

  1. Користите RS485 кабл за повезивање инвертора и литијумске батерије.
  2. Укључите литијумску батерију.

Setting for Lithium Battery without Communication:

If using a lithium battery without communication, obtain the battery's BMS specifications (Max charging voltagе, Максимална струја пуњења, Заштита од пражњењаtage) and manually set the inverter's battery type to "User-Defined" (program 05). Then, set the C.V voltagе, плутајуће пуњење волtage, and max charging current protection accordingly. It is recommended to complete these settings before turning on the inverter's output.

6. Одржавање

6.1 Battery Equalization

The equalization function helps reverse negative chemical effects like stratification and removes sulfate crystals that can reduce battery capacity. It is recommended to equalize batteries periodically.

Како применити функцију изједначавања:

First, enable the battery equalization function in LCD setting program 33. Then, apply it by either:

  1. Подешавање интервала изједначавања у програму 37.
  2. Активирање изједначавања одмах у програму 39.

Када изједначити:

У плутају сtage, when the set equalization interval is reached or equalization is actively initiated, the controller will enter the Equalize stage.

Изједначите време пуњења и време чекања:

During the Equalize stage, the controller charges the battery until it reaches the battery equalization voltage. Constant-voltage regulation then maintains this voltage. The battery remains in this stage until the set battery equalized time expires. If the battery voltagе не достиже запремину изједначавањаtage by the end of the equalized time, the charge controller will extend the time. If the battery voltage is still low after the equalized timeout, the controller will stop equalization and return to the float stage.

КСНУМКС. Решавање проблема

This section provides guidance on common issues, fault codes, and warning indicators. For more detailed troubleshooting, refer to the comprehensive PDF user manual.

7.1 Fault Reference Codes

Fault Codes and Events
Код грешкеДогађај грешкеИкона на ЛЦД-у
01Прегревање инверторског модула01
02Превише температуре ДЦДЦ модула02
03Баттери волtagе је превисоко03
04Превише температуре ПВ модула04
05Кратак спој на излазу.05
06Оутпут волtagе је превисоко.06
07Време истека преоптерећења07
08Бус волtagе је превисоко08
09Меки старт аутобуса није успео09
10ПВ преко струје10
11ПВ преко волtage11
12ДЦДЦ преко струје12
13Прекомерна струја или пренапон13
14Бус волtagе је прениско14
15Инвертер није успео (самопровера)15
18Оп-струјни офсет је превисок18
19Помак струје инвертера је превисок19
20Помак ДЦ/ДЦ струје је превисок20
21Помак ПВ струје је превисок21
22Оутпут волtagе је прениско22
23Негативна снага претварача23

7.2 Индикатори упозорења

Warning Codes and Events
Код упозорењаДогађај упозорењаЗвучни алармИкона трепери
02Температура је превисокаЗвук три пута сваке секунде02
04Ниска батеријаБип једном сваке секунде04
07ПреоптерећењеЗвук једном у 0.5 секунди07
10Смањење излазне снагеЗвук двапут сваких 3 секунди10
14Вентилатор блокиранНиједан14
15ПВ енергија је нискаЗвук двапут сваких 3 секунди15
19Комуникација са литијумском батеријом није успелаЗвук једном у 0.5 секунди19
21Прекомерна струја литијумске батеријеНиједан21
E9Изједначавање батеријеНиједанE9
bPБатерија није повезанаНиједанbP

8. Спецификације

The following tables provide detailed technical specifications for the SANDISOLAR SD-HYM-2430HW-US Solar Inverter.

Табела 8.1: Спецификације линијског режима
ИНВЕРТЕР МОДЕЛ3КВА
Улазни волtagе Таласни обликСинусоидални (услужни или генератор)
Номинални улаз Волtage120Вац
Лов Лосс Волtage95Вац±7В (УПС); 70Вац±7В (апарати)
Лов Лосс Ретурн Волtage100Вац±7В (УПС); 75Вац±7В (апарати)
Хигх Лосс Волtage140Вац±7В
Хигх Лосс Ретурн Волtage135Вац±7В
Макс. АЦ Инпут Волtage150Вац
Номинална улазна фреквенција50Хз / 60Хз (аутоматско откривање)
Ниска фреквенција губиткаКСНУМКС ± КСНУМКСХз
Ниска повратна фреквенција губитакаКСНУМКС ± КСНУМКСХз
Висока фреквенција губиткаКСНУМКС ± КСНУМКСХз
Висока учесталост поврата губиткаКСНУМКС ± КСНУМКСХз
Заштита од кратког споја на излазуРежим батерије: Електронска кола
Ефикасност (линијски режим)>95% (номинално R оптерећење, батерија потпуно напуњена)
Трансфер Тиме10мс типично (УПС); 20 мс типично (апарати)
Смањење излазне снаге: Када АЦ улазна волtagе падне на 95В, излазна снага ће бити смањена.Output power derating curve
Табела 8.2: Спецификације инверторског режима
ИНВЕРТЕР МОДЕЛ3КВА
Називна излазна снага3.0КВА/3.0КВ
Оутпут Волtagе Таласни обликЧисти синусни талас
Оутпут Волtagе Регулатива120Вац±5%
Излазна фреквенција50Хз или 60Хз
Пеак Еффициенци94%
Капацитет пренапона2* називна снага за 5 секунди
Номинал ДЦ Инпут Волtage24Вдц
Цолд Старт Волtage23.0Вдц
Потрошња енергије без оптерећења<55В
Лов ДЦ Варнинг Волtage (Just for AGM and Flooded)@оптерећење < 20%: 22.0 V једносмерне струје; @20% ≤ оптерећење < 50%: 21.4 V једносмерне струје; @оптерећење ≥ 50%: 20.4 V једносмерне струје
Лов ДЦ Варнинг Ретурн Волtage (Just for AGM and Flooded)@оптерећење < 20%: 23.0 V једносмерне струје; @20% ≤ оптерећење < 50%: 22.4 V једносмерне струје; @оптерећење ≥ 50%: 21.2 V једносмерне струје
Лов ДЦ Цут-офф Волtage (Just for AGM and Flooded)@оптерећење < 20%: 21.0 V једносмерне струје; @20% ≤ оптерећење < 50%: 20.4 V једносмерне струје; @оптерећење ≥ 50%: 19.2 V једносмерне струје
Table 8.3: Charge Mode Specifications
Услужни режим пуњења3КВА
Max Charging Current (PV+AC) (@VI/P=230Vac)100Amp
Max Charging Current (AC) (@VI/P=230Vac)60Amp
Булк Цхаргинг Волtagе (Поплављена батерија)29.2Вдц
Булк Цхаргинг Волtagе (AGM / гел батерија)28.2Вдц
Флоатинг Цхаргинг Волtage27Вдц
Заштита од преоптерећења32Вдц
Алгоритам пуњења3-корак
Solar Input Rated Power4000В
Макс. ПВ Арраи Опен Цирцуит Волtage500Вдц
ПВ Арраи МППТ Волtagе Распон60Вдц~500Вдц
Макс. Инпут Цуррент27А
Max. Charging Current (PV)100А
Табела 8.4: Опште спецификације
ИНВЕРТЕР МОДЕЛ3КВА
Опсег радне температуре-10°Ц до 50°Ц
Температура складиштења-15°Ц до 60°Ц
Влажност5% до 95% релативне влажности (без кондензације)
Dimensions (D*W*H), mm312.4 × 350 × 114.5
Нето тежина, кг8.5
Комуникациони интерфејсDry contact + RS485 + WIFI
Ингресс ПротецтионИП21

9. Wi-Fi Plug Pro Quick Installation Guideline

The inverter includes built-in WiFi for remote monitoring and control via the SmartESS App.

9.1 Installing the Wireless Antenna

Refer to the schematic diagram in the PDF user manual for instructions on removing and installing the wireless antenna.

9.2 Додајте Даталоггер

  1. Log in to your SmartESS account and click the Datalogger button. Tap the "+" button on the top-right corner of the datalogger page.
  2. Follow the prompts to enter the information and finish adding the datalogger. The PN number is located next to the machine appliance label. The initial password is 12345678.

9.3 Преузмите АПЛИКАЦИЈУ

  1. Scan the QR code provided in the PDF manual or search for "SmartESS" in your iPhone App Store or Android phone's app store to download the application.
  2. Open the APP, click the "Registration" button, and select "Mobile phone Registration" or "Email Registration".
  3. Укључите Блутут или Ви-Фи по потреби.

9.4 Bluetooth Connection to the Digital Collector

  1. Click the "Toolbox" in the app and select "BLE network" or "Wi-Fi network" as required.
  2. If you choose the Bluetooth distribution network, the app will automatically scan for nearby devices on the "Bluetooth Pairing" page. Find the PN corresponding to your digital collector and click "Connect".

9.5 Networking Settings

  1. Select the corresponding 2.4G WiFi network, fill in the password, and click "Start Connecting to the Network".
SmartESS App interface for monitoring and control
Figure 9.1: SmartESS App interface for monitoring and controlling the inverter.

10. Гаранција и подршка

The SANDISOLAR SD-HYM-2430HW-US Solar Inverter comes with a 2-year warranty from the store. For any issues or support, please contact the seller directly.

Информације о гаранцији и сервису
Figure 10.1: Warranty and service details, including a 2-year warranty.
Documents - SANDISOLAR – SD-HYM-2430HW-US

нема релевантних докумената