Cecilware 85-1155

Cecilware X006A Sight Gauge Glass User Manual

Model: 85-1155 | Brand: Cecilware

1. Увод

This user manual provides essential information for the proper installation, operation, and maintenance of the Cecilware X006A Sight Gauge Glass. This component is designed for use in commercial coffee brewing equipment and similar applications to provide a clear indication of liquid levels. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. Карактеристике производа

Cecilware X006A Sight Gauge Glass

Figure 2.1: The Cecilware X006A Sight Gauge Glass, a clear cylindrical glass tube used for liquid level indication.

3. Подешавање и инсталација

The Cecilware X006A Sight Gauge Glass is a replacement part. Installation should be performed by qualified personnel familiar with the specific equipment it is being installed into.

  1. Безбедност на првом месту: Ensure the equipment is powered off, unplugged, and completely cooled down before beginning any installation or maintenance. Drain any liquid from the system.
  2. Remove Old Gauge: Carefully remove the old or broken sight gauge glass. Note the orientation and any seals or gaskets that were in place.
  3. Прегледајте заптивке: Inspect the existing seals and gaskets. Replace them if they show any signs of wear, cracking, or damage. Using new seals is highly recommended to prevent leaks.
  4. Insert New Glass: Gently insert the new Cecilware X006A Sight Gauge Glass into the designated fittings. Do not force the glass.
  5. Secure Fittings: Secure the fittings, ensuring they are tightened sufficiently to create a watertight seal, but avoid over-tightening which can crack the glass.
  6. Тест цурења: After installation, slowly refill the system and carefully check for any leaks around the new sight glass. Address any leaks immediately.

4. Упутство за употребу

The sight gauge glass itself does not require active operation. Its function is passive, providing a visual indication of the liquid level within the connected reservoir or tank.

5. Одржавање

Proper maintenance extends the life of the sight gauge glass and ensures accurate readings.

КСНУМКС. Решавање проблема

ПроблемМогући узрокРешење
Liquid level unclear/obscuredInternal staining or mineral buildup; external dirt.Clean the glass externally. If internal, follow equipment cleaning procedures or replace the glass.
Leakage around the glassDamaged or worn seals/gaskets; improper installation/tightening.Inspect and replace seals/gaskets. Re-tighten fittings carefully, ensuring not to over-tighten.
Glass is cracked or chippedPhysical impact; over-tightening during installation; thermal shock.Immediately replace the sight gauge glass. Ensure correct installation procedures are followed.

7. Спецификације

АтрибутВалуе
Број модела85-1155 (X006A)
БрандЦецилваре
Материјалстакло
Димензије (пречник к дужина)0.625" x 8.0" (approx. 5/8" x 8")
Тежина артикла2.88 унци
УПЦ851155785119

8. Гаранција и подршка

Specific warranty information for the Cecilware X006A Sight Gauge Glass is not provided in this manual. For warranty details, please refer to the documentation provided with your original equipment or contact Cecilware directly.

For technical support or replacement parts, please contact your equipment supplier or the manufacturer, Cecilware, through their official webсајт или канали за корисничку подршку.

Напомена о видео записима: No official product videos from the seller are available for this specific product at this time.