This manual provides essential information for the safe and efficient installation, operation, and maintenance of the DANFOSS BFP 21R3 Burner Oil Pump, model number 071N0109. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

Слика 1: Опште view of the DANFOSS BFP 21R3 Burner Oil Pump.
2. Безбедносне информације
Always observe general safety precautions when working with fuel systems and electrical components. Failure to follow these instructions may result in property damage, serious injury, or death.
- Ensure the power supply to the burner system is disconnected before installation, maintenance, or troubleshooting.
- Носите одговарајућу личну заштитну опрему (ЛЗО), укључујући рукавице и заштиту за очи.
- Handle fuel with care. Fuel is flammable and can cause skin irritation.
- Installation and service should only be performed by qualified personnel.
- Check for leaks after installation and before operating the system.
- Do not modify the pump or its components. Use only genuine DANFOSS replacement parts.
3. Производ је готовview
The DANFOSS BFP 21R3 is a compact burner oil pump designed for use in oil burner systems. It is engineered for reliable fuel delivery and pressure regulation. The pump features a robust metal construction and is suitable for industrial applications.

Слика 2: Страна view of the pump, highlighting the 'P' (pressure) and 'V' (return) ports, and model identification.
Кључне карактеристике укључују:
- Модел: BFP 21R3
- Број дела: 071Н0109
- Материјал: Метал
- Боја: Црно
- апликација: Burner Oil Systems

Слика 3: Врх view of the pump, showing the electrical connector for power supply.
4. Подешавање и инсталација
Proper installation is crucial for the pump's performance and longevity. Refer to your burner manufacturer's instructions for specific mounting requirements.
4.1 Монтажа
- Mount the pump securely to the burner motor or a stable surface using appropriate fasteners.
- Ensure the pump shaft aligns correctly with the motor coupling.

Слика 4: Дно view of the pump, illustrating the drive shaft and mounting screw locations.
4.2 Прикључци водова за гориво
Connect the fuel lines as follows:
- Inlet (Suction) Line: Connect the fuel supply line to the designated inlet port. Ensure a tight, leak-free connection.
- Nozzle Line (Pressure): Connect the line leading to the burner nozzle to the pressure port (marked 'P' on some models).
- Повратна линија: If applicable, connect the return line to the return port (marked 'V' on some models) to send excess fuel back to the tank. For single-pipe systems, the return port must be plugged.
4.3 Електричне везе
Connect the pump's electrical terminals to the burner control system according to the burner manufacturer's wiring diagram. Ensure correct voltage and polarity. All electrical work must comply with local codes and regulations.
4.4 Пумпање пумпе
After installation, the pump must be primed to remove air from the fuel lines. This is typically done by running the burner for a short period until a steady flame is established. Some pumps may have a bleed screw for manual air removal.
5. Упутство за употребу
Once installed and primed, the DANFOSS BFP 21R3 pump operates automatically in conjunction with the burner control system. The pump maintains the required fuel pressure for efficient combustion.
5.1 Подешавање притиска
The pump's pressure can be adjusted via a pressure regulating screw, typically located on the pump body. Use a pressure gauge to set the desired operating pressure as specified by the burner manufacturer. Turn the screw clockwise to increase pressure and counter-clockwise to decrease pressure.
6. Одржавање
Regular maintenance ensures optimal performance and extends the life of the pump.
6.1 Рутинске провере
- Inspect fuel lines for leaks, cracks, or damage.
- Check electrical connections for tightness and corrosion.
- Ослушкујте необичне звукове током рада, који могу указивати на проблем.
6.2 Замена филтера
The pump typically contains an internal filter that should be inspected and replaced periodically, usually annually or as recommended by the burner manufacturer. A clogged filter can restrict fuel flow and reduce pump performance.

Figure 5: Close-up of the pump's drive shaft, which connects to the motor.
КСНУМКС. Решавање проблема
This section outlines common issues and potential solutions. Always disconnect power before performing any troubleshooting steps.
| Проблем | Могући узрок | Решење |
|---|---|---|
| Нема протока уља | Clogged filter, air in lines, faulty motor, incorrect rotation | Clean/replace filter, bleed air, check motor, verify pump rotation |
| Низак притисак уља | Clogged filter, worn pump components, incorrect pressure setting | Clean/replace filter, inspect pump, adjust pressure regulator |
| Прекомерна бука | Air in lines, loose mounting, worn bearings | Bleed air, tighten mounting bolts, inspect for wear |
| Уље цури | Loose fittings, damaged seals | Tighten connections, replace seals |
8. Спецификације
| Спецификација | Валуе |
|---|---|
| Произвођач | ДАНФОСС |
| Број модела | BFP 21R3 |
| Парт Нумбер | 071Н0109 |
| Материјал | Метал |
| Боја | Црно |
| Стиле | Индустриал |
9. Гаранција и подршка
For warranty information or technical support, please contact your authorized DANFOSS dealer or the seller from whom the product was purchased. Keep your proof of purchase for warranty claims.