CAPI 1.1 and CAPI 2.0 info values with their appropriate error-codes associated with the capiInfoNumber field are as follows. Both CAPI 1.1 and 2.0 info values are arranged by error class.

CAPI 1.1 Info Values

Error Class 10
Formal error messages and errors during management of Message Queues.

0к1001 Application registration error
0к1002 Wrong application id
0к1003 Message error
0к1004 Wrong capi command
0к1005 Message queue full
0к1006 Message queue empty
0к1007 Messages lost
0к1008 Error during deinstallation

Error Class 20
Addressing errors.

0к2001 Wrong controller
0к2002 Wrong PLCI
0к2003 Wrong NCCI
0к2004 Погрешан тип

Error Class 31
Incorrect parameters.

0к3101 B-channel incorrectly coded
0к3102 Info mask incorrectly coded
0к3103 Service SI mask incorrectly coded
0к3104 Service EAZ mask incorrectly coded
0к3105 B2 protocol incorrect
0к3106 Dlpd incorrect
0к3107 B3 protocol incorrect
0к3108 NCPD incorrect
0к3109 NCPI incorrect
0к310а Flags incorrectly coded

Error Class 32
Unsupported parameters.

0к3201 Грешка контролера
0к3202 Conflict between registrations
0к3203 Function is not supported
0к3204 PLCI not active
0к3205 NCCI not active
0к3206 B2 protocol not supported
0к3207 Change of B2 protocol not possible in this state
0к3208 B3 protocol not supported
0к3209 Change of B3 protocol not possible in this state
0к320а Parameters used not supported in DLPD
0к320б Parameters used not supported in NCPD
0к320ц Parameters used not supported in NCPI
0к320д Data length not supported
0к320е DTMF number unknown

Error Class 33
Network errors.

0к3301 Error on setup of D-channel layer 1
0к3302 Error on setup of D-channel layer 2
0к3303 Error on setup of B-channel layer 1
0к3304 Error on setup of B-channel layer 2
0к3305 Abort D-channel layer 1
0к3306 Abort D-channel layer 2
0к3307 Abort D-channel layer 3
0к3308 Abort B-channel layer 1
0к3309 Abort B-channel layer 2
0к330а Abort B-channel layer 3
0к330б Re-establish B-channel layer 2
0к330ц Re-establish B-channel layer 3

Error Class 34
Network messages (whereby xx refers to the related 1TR6 Error-Cause).

0к3400 Normal call clearing
0к3480 Normal call clearing
0к3481 Invalid call reference value
0к3483 Bearer service not implemented
0к3487 Call identity does not exist
0к3488 Call identity in use
0к348а No channel available
0к3490 Requested facility not implemented
0к3491 Requested facility not subscribed
0к34а0 Outgoing calls barred
0к34а1 Корисник је заузет
0к34а2 Negative GBG Comparison
0к34а5 As SPV not aloud
0к34б0 Reverse charging not allowed at origination
0к34б1 Reverse charging not allowed at destination
0к34б2 Reverse charging rejected
0к34б5 Destination not obtainable
0к34б8 Number changed
0к34б9 Неисправно
0x34ba User not responding
0x34bb User access busy
0x34bd Incoming calls barred
0x34be Позив је одбијен
0к34д9 Загушење мреже
0x34da Remote user initiated
0к34ф0 Local procedure error
0к34ф1 Remote procedure error
0к34ф2 Remote user suspended
0к34ф3 Remote user resumed
0к34фф User info discarded locally

Error Class 40
FAX-G3 Errors.

0к4001 Remote station is not a fax G3 machine
0к4002 Local fax module busy
0к4003 Disconnected during transfer (remote abort)
0к4004 Disconnected before transfer (training error)
0к4005 Disconnected during transfer (local tx data underrun)
0к4006 Fax module temporary disabled
0к4007 Local disconnect (local abort)
0к4008 Disconnect during transfer (remote procedure error)
0к4009 Remote disconnect (remote abort)
0к400а Line Disconnect during transfer
0к400б Disconnect before transfer
0к400ц Local Disconnect (SFF coding error)

CAPI 2.0 Info Values

Error Class 00
Informative values (corresponding message was processed).

0к0001 NCPI not supported by current protocol, NCPI ignored
0к0002 Flags not supported by current protocol, flags ignored
0к0003 Alert already sent by another application

Error Class 10
Error information concerning CAPI_REGISTER.

0к1001 Превише апликација
0к1002 Logical block size too small, must be at least 128 bytes
0к1003 Buffer exceeds 64 kByte
0к1004 Message buffer size too small, must be at least 1024 byte
0к1005 Max. number of logical connections not supported
0к1006 Резервисано
0к1007 The message could not be accepted because of an internal busy condition
0к1008 OS Resource error (e.g. no memory)
0к1009 COMMON-ISDN-API not installed
0к100а Controller does not support external equipment
0к100б Controller does only support external equipment

Error Class 11
Error information concerning message exchange functions.

0к1101 Illegal application number
0к1102 Illegal command or subcommand or message length less than 12 octets
0к1103 The message could not be accepted because of a queue full condition
0к1104 Queue is empty
0к1105 Queue overflow, a message was lost
0к1106 Unknown notification parameter
0к1107 The message could not be accepted because of an internal busy condition
0к1108 OS resource error (e.g. no memory)
0к1109 COMMON-ISDN-API not installed
0к110а Controller does not support external equipment
0к110б Controller does only support external equipment

Error Class 20
Error information concerning resource/coding problems.

0к2001 Message not supported in current state
0к2002 Illegal Controller/PLCI/NCCI
0к2003 Out of PLCI
0к2004 Out of NCCI
0к2005 Out of LISTEN
0к2006 Out of FAX resources (protocol T.30)
0к2007 Illegal Message parameter coding

Error Class 30
Error information concerning requested services.

0к3001 B1 protocol not supported
0к3002 B2 protocol not supported
0к3003 B3 protocol not supported
0к3004 B1 protocol parameter not supported
0к3005 B2 protocol parameter not supported
0к3006 B3 protocol parameter not supported
0к3007 B protocol combination not supported
0к3008 NCPI not supported
0к3009 CIP Value unknown
0к300а Flags not supported (reserved bits)
0к300б Facility not supported
0к300ц Data length not supported by correct protocol
0к300д Reset procedure not supported by current protocol

Error Class 33
Protocol error reasons.

  • 0x3301 Protocol error layer 1 (broken line or B-channel removed by signaling protocol)
  • 0x3302 Protocol error layer 2
  • 0x3303 Protocol error layer 3
  • 0x3304 Another application got that call
  • 0x3311 Connecting not successful (remote station is no FAX G3 machine)
  • 0x3312 Connecting not successful (training error)
  • 0x3313 Disconnected before transfer (remote station does not support transfer mode, e.g. resolution)
  • 0x3314 Disconnected during transfer (remote abort)
  • 0x3315 Disconnected during transfer (remote procedure error, e.g. unsuccessful repetition of T.30 commands)
  • 0x3316 Disconnected during transfer (local tx data underrun)
  • 0x3317 Disconnected during transfer (local rx data overflow)
  • 0x3318 Disconnected during transfer (local abort)
  • 0x3319 Illegal parameter coding (e.g. SFF coding error)

Error Class 34
Disconnect cause from the network according to ETS 300102-1/Q.931. In the field ‘xx’ the cause value received within a cause information element (octet 4) from the network is indicated.

  • 0x3481 Unallocated (unassigned) number
  • 0x3482 No route to specified transit network
  • 0x3483 No route to destination
  • 0x3486 Channel unacceptable
  • 0x3487 Call awarded and being delivered in an established channel
  • 0x3490 Normal call clearing
  • 0x3491 User busy
  • 0x3492 No user responding
  • 0x3493 No answer from user (user alerted)
  • 0x3495 Call rejected
  • 0x3496 Number changed
  • 0x349a Non-selected user clearing
  • 0x349b Destination out of order
  • 0x349c Invalid number format
  • 0x349d Facility rejected
  • 0x349e Response to STATUS ENQUIRY
  • 0x349f Normal, unspecified
  • 0x34a2 No circuit / channel available
  • 0x34a6 Network out of order
  • 0x34a9 Temporary failure
  • 0x34aa Switching equipment congestion
  • 0x34ab Access information discarded
  • 0x34ac Requested circuit / channel not available
  • 0x34af Resources unavailable, unspecified
  • 0x34b1 Quality of service unavailable
  • 0x34b2 Requested facility not subscribed
  • 0x34b9 Bearer capability not authorized
  • 0x34ba Bearer capability not presently available
  • 0x34bf Service or option not available, unspecified
  • 0x34c1 Bearer capability not implemented
  • 0x34c2 Channel type not implemented
  • 0x34c5 Requested facility not implemented
  • 0x34c6 Only restricted digital information bearer capability is available
  • 0x34cf Service or option not implemented, unspecified
  • 0x34d1 Invalid call reference value
  • 0x34d2 Identified channel does not exist
  • 0x34d3 A suspended call exists, but this call identity does not
  • 0x34d4 Call identity in use
  • 0x34d5 No call suspended
  • 0x34d6 Call having the requested call identity has been cleared
  • 0x34d8 Incompatible destination
  • 0x34db Invalid transit network selection
  • 0x34df Invalid message, unspecified
  • 0x34e0 Mandatory information element is missing
  • 0x34e1 Message type non-existent or not implemented
  • 0x34e2 Message not compatible with call state or message type non-existent or not implemented
  • 0x34e3 Information element non-existent or not implemented
  • 0x34e4 Invalid information element contents
  • 0x34e5 Message not compatible with call state
  • 0x34e6 Recovery on timer expiry
  • 0x34ef Protocol error, unspecified
  • 0x34ff Interworking, unspecified

Документи / Ресурси

PDF thumbnailCAPI Software System
Owner's Manual · CAPI Software System, Software System

Референце

Поставите питање

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Поставите питање

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.