📘 Terragene manuals • Free online PDFs
Terragene logo

Terragene Manuals & User Guides

Terragene provides biotechnology-based infection prevention solutions, including advanced auto-readers and biological indicators for sterilization control.

Tip: include the full model number printed on your Terragene label for the best match.

About Terragene manuals on Manuals.plus

Terragene Sterilization & Infection Control

Terragene is a biotechnology company specializing in infection prevention and sterilization monitoring solutions for healthcare, laboratory, and pharmaceutical environments. Their extensive product lineup includes the Bionova line of Self-Contained Biological Indicators (SCBIs) designed for steam, ethylene oxide, and vaporized hydrogen peroxide sterilization.

Additionally, Terragene manufactures advanced Auto-reader Incubators—such as the Bionova Photon, Hyper (BT98), and IC10/20FR—which offer hyper-rapid readouts to streamline sterile processing workflows. Their physical devices are safely integrated with the Bionova Cloud traceability software and smartphone applications, enabling precise, automated quality control from washing to final sterilization validation.

Terragene Bionova Auto-Readers

To assure proper readouts, Terragene provides purpose-built auto-reader incubators like the Bionova IC10/20FR and Hyper Auto-reader series. These devices guarantee correct temperature regulation and utilize fluorescence techniques to provide accurate sterility confirmation in mere minutes or seconds. Before operating these complex bio-medical devices, it is extremely important to review the correct user manuals for incubation parameters and safety practices.

Terragene manuals

Најновији приручници од manuals+ курирано за овај бренд.

Terragene PCD98 Biological Indicator User Guide

29. јуна 2026. године
Terragene PCD98 Biological Indicator Introduction Effective sterilization monitoring in healthcare facilities is a critical component of infection prevention programs. For vaporized hydrogen peroxide (VH2O2) sterilization processes, the use of biological…

Terragene BT98 Biological Indicator Instruction Manual

6. марта 2026. године
BT98 Biological Indicator R04 / 08.2025 Hyper Rapid Readout Fluorescence System Product authorized by ANMAT PM 1614-1 Hole with special paper Plastic cap Plastic tube Identification label Process indicator Glass…

Terragene IC10 20FR Bionova Auto Reader Instruction Manual

31. децембра 2025. године
Terragene IC10 20FR Bionova Auto Reader Specifications Product: Biological Indicators and Hygiene Monitoring System Material: Contains dry natural rubber Expiry Date: May 2025 Power Supply: 12 Volts DC Composition Product…

Terragene IC10 Auto Reader Incubator User Guide

25. новембар 2025
Terragene IC10 Auto Reader Incubator Bionova® IC10/20FRLCD Auto-reader Symbols Humidity limitation Temperature limit Caution Caution, hot surface CE Mark Direct current For indoor use only Keep away from sunlight Batch…

Terragene IU-IC1020-DUAL двоструки инкубатор за биолошке индикаторе и системе за праћење хигијене - упутство за употребу

13. октобра 2025. године
Terragene IU-IC1020-DUAL Dual Incubator For Biological Indicators and Hygiene Monitoring Systems  Product Information Model: IC10/20 Revision: 22/04/2022 Language: English, Italian, Japanese Function: Dual Incubator For Biological Indicators and Hygiene Monitoring…

MiniBio Auto-reader Incubator Product Overview

производ завршенview
Technical specifications, usage guidelines, and regulatory information for the Terragene MiniBio Auto-reader Incubator, designed for rapid biological indicator readout.

Bionova® MiniBio Auto-reader User Manual

приручник
Official user manual for the Bionova® MiniBio Auto-reader by Terragene, covering setup, operation, configuration, and maintenance for sterilization process control.

Bionova® Hyper Auto-reader: User Manual and Quick Start Guide

Упутство за употребу
Comprehensive guide for the Terragene Bionova® Hyper Auto-reader, detailing its features, setup, operation, safety precautions, technical specifications, and troubleshooting for monitoring sterilization processes using SCBI indicators.

Terragene support FAQ

Честа питања о упутствима, регистрацији и подршци за овај бренд.

  • How do I store Terragene Bionova Biological Indicators?

    Store Bionova Biological Indicators in a dark place at an ambient temperature between 10-30 °C and 30-80% relative humidity. Never freeze them, and ensure they are not stored near sterilizing agents or other chemical products.

  • Why do I need a positive control when running a sterilization cycle check?

    Using a non-sterilized Self-Contained Biological Indicator (SCBI) from the exact same batch as a positive control ensures that the incubation conditions were met properly, the medium promotes rapid growth, and that the spore viability hasn't been compromised due to improper storage. A valid test requires the positive control to show positive fluorescence readout.

  • How do I use a Bionova Auto-reader Incubator?

    First, check your specific Terragene SCBI to ensure it matches the appropriate incubation time and temperature. Once an SCBI has been removed from a finished sterilization cycle and allowed to cool, press its lid to seal the tube, crush the internal ampoule using the provided ampoule crusher, and shake vigorously. Place the wetted SCBI into an empty position in the designated Bionova Auto-reader to begin automated fluorescence monitoring.

  • What does a color change to green or yellow mean on the indicators?

    For BT98 SCBIs, a process label color change from purple to green indicates exposure to hydrogen peroxide, though it does not guarantee sterilization. If after the incubation period the culture medium itself changes color (typically to yellow), it denotes a positive result (presence of living spores), indicating a sterilization process failure.