ENTTEC 73539 DIN PIXIE
Информације о производу
Спецификације:
- Водич за креирање прилагођеног протокола
- Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
- Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2
Упутства за употребу производа
Увод:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
Захтеви за подешавање:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
КОМПАТИБИЛНИ ФИРМВЕР
Креирање прилагођеног протокола је представљено у следећим ЕНТТЕЦ пиксел контролерима:
| СКУ | Производ | Верзија фирмвера |
| 73539 | ДИН ПИКСИЕ | ВКСНУМКС или изнад |
| 70067 | ПИКСЕЛАТОР МИНИ | ВКСНУМКС или изнад |
| 70068 | Пикселатор мини МК2 | ВКСНУМКС или изнад |
| 71521 | ОЦТО МК2 | ВКСНУМКС или изнад |
| 71522 | ОЦТО МК3 | ВКСНУМКС или изнад |
УВОД
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- Ова функција омогућава корисницима да подесе јачину звукаtagТајминг на основу подржаних протокола ако се метод преноса података поклапа са било којим од наших подржаних протокола.
- Овај документ пружа упутства за подешавање за креирање прилагођеног протокола пиксела и проверу критеријума.
ЗАХТЕВИ ЗА ПОДЕШАВАЊЕ
За креирање прилагођеног протокола потребно је следеће:
- Датасхеет: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- Уређај: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
ВОДИЧ ЗА КРЕИРАЊЕ ПРИЛАГОЂЕНОГ ПРОТОКОЛА
Ова функција омогућава корисницима да подесе обим податакаtage timing to meet specific protocol needs. To create a custom protocol:
- Проверите листу података за компатибилни пиксел протокол.
- Идите до корисничког интерфејса уређаја да бисте омогућили функцију прилагођеног протокола.
- Подесите запремину података пиксел уређајаtagе мерење времена преко web интерфејс према техничком листу произвођача.
Корак 1: Проверите листу података за компатибилни протокол
- Проверите метод преноса података вашег жељеног протокола из табеле са подацима.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Најчешћи метод преноси податке без додатних битова (нпр. Д1-Д2-Д3…Дн).
Exampле: Информације преузете из листа података ВБ2812Б
- Неки протоколи, попут ТМ1814, укључују додатне податке на предњој страни (нпр. Ц1-Ц2-Д1-Д2…Дн).
Exampле: Информације преузете из таблице података ТМ1814
- Најчешћи метод преноси податке без додатних битова (нпр. Д1-Д2-Д3…Дн).
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Номинујте одговарајући протокол који уређај подржава (или изаберите неки од горе наведених нпрample) that shares the same data transmission method as your desired pixel protocol.
- Пређите на корак 2 за даљу конфигурацију.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web интерфејс
- Гоогле Цхроме се предлаже као web browser to access the OCTO/PIXELATOR MINI’s web интерфејс.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webсајт ввв.енттец.цом да преузмете апликацију.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
Идите на излаз на који је повезан жељени пиксел. Изаберите протокол пиксела са падајуће листе који дели исти метод преноса верификован у кораку 1.
- Enable Custom protocol (Continue to Step 3)
Омогућите поље за потврду „Прилагођено“ да бисте приступили подацима волtagе подешавање времена. Означите да бисте онемогућили прилагођени протокол.
За ДИН ПИКСИЕ
- Повежите ДИН ПИКСИЕ са рачунаром користећи УСБ Типе-Б.
- Покрените ЕМУ софтвер.
- Скенирајте уређај и кликните на Цонф откривеног ДИН ПИКСИЕ.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
Корак 3: Подесите прилагођену волtagе тајминг
- Ускладите волtagе тајминг на таблици података вашег жељеног протокола. Прилагођени протокол захтева 4 улаза за комплетирање података волtagе подешавање времена:
Волtage Timing Definition Бит 0 Хигх Тиме (Т0Х) Волtagе крајње време потребно за код 0. Бит 1 Хигх Тиме (Т1Х) Волtagе крајње време потребно за код 1. Overall Bit Time: Укупна волtage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
Ресет Тиме Укупна волtagМало времена потребно за ресетовање преноса података између сваке групе података. 
- Датасхеет – Дата волtagе информације о времену нпрample
Из листа са подацима ВБ2818Б- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltagе временски опсег.
- Попуните волtagВременски опсег у прилагођеном пољу у Оутпут Сеттингс.

ВАЖНО
- ENTTEC recommends taking the median value of the range for the start.
- Корисник ће морати да САЧУВА подешавања да би измењена вредност ступила на снагу.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
ЗАКЉУЧАК
- Овај водич је показао како да подесите прилагођени протокол за ЕНТТЕЦ уређаје који испуњавају услове и пружио је техничко знање о верификацији листа података о вашим жељеним пикселским уређајима.
- Пратећи ове кораке, корисници могу да креирају прилагођени протокол пиксела који се не налази на падајућој листи без чекања на техничку подршку или ново издање фирмвера. Ако имате питања или имате потешкоћа да пронађете праве информације, обратите се нашем пријатељском тиму за подршку у локалним канцеларијама.
ФАК
How do I access the device settings page on my computer?
You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web претраживач.
Can I create a custom protocol without the datasheet?
It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.